Theory to boil-off gas cooled shields for cryogenic storage vessels
Authors:A Hofmann
Affiliation:Gartenstr. 51, 82515 Wolfratshausen, Germany
Abstract:An intermediate refrigeration with boil-off gas cooled shields using the boil-off gas stream is an alternative method to the conventional intermediate refrigeration with a cryogenic liquid.By using an analytical calculation method relations are derived, which enable complete predictions about the effectiveness of an intermediate refrigeration with boil-off gas cooled shields as a function of the number of shields for the different stored cryogenic liquids. For this theoretical derivation however, the restrictive assumption must be made that the thermal conductivity of the used insulation material has a constant value between the considered temperature boundaries.For purposes of a more exact calculation a numerical method is therefore suggested, which takes into consideration that the thermal conductivity is temperature-dependent. For a liquid hydrogen storage vessel with a perlite-vacuum insulation e.g., the effectiveness of one shield and its equilibrium temperature are given as a function of the position of the shield in the insulation space.
Keywords:Shield  Storage vessel  Boil-off gas  Cryostats