首页 | 官方网站   微博 | 高级检索  
     

燃煤电厂可凝结颗粒物(SO3)采样方法研究
引用本文:张德君,刘含笑,赵琳,袁伟锋,方小伟,许东旭,骆建友.燃煤电厂可凝结颗粒物(SO3)采样方法研究[J].中国电力,2018,51(6):33-36,149.
作者姓名:张德君  刘含笑  赵琳  袁伟锋  方小伟  许东旭  骆建友
作者单位:1. 吉林电力股份有限公司四平热电公司, 吉林 四平 136001; 2. 浙江菲达环保科技股份有限公司, 浙江 诸暨 311800
基金项目:国家重点研发计划资助项目(2016YFC0203704)。
摘    要:现有的可凝结颗粒物(SO3)采样方法存在弊端,对传统的采样单元进行优化改进,以提高SO3捕集效率。分别对几种采样方案进行了比校,包括1级垂直式与水平式冷凝盘以及冷凝盘管与异丙醇吸收法。对于烟气中SO3的捕集效果,特制的垂直式及水平式冷凝盘效果相当,2级冷凝盘管串联效果最好,异丙醇吸收法次之,1级冷凝盘管最差。据此,提出了2级垂直式冷凝盘管(65℃恒温水浴)+80%异丙醇吸收(0℃冰浴)的最佳捕集方案,并开展现场实测。结果表明,上述3个单元均对SO3有所捕集,第1级盘管捕集量最大,之后依次递减,第2级盘管和异丙醇吸收单元所捕集的SO3占比为26%~40%。

关 键 词:燃煤电厂  超低排放  SO3  SO3采集  控制冷凝  异丙醇吸收  SO3捕集效果  
收稿时间:2017-09-25
修稿时间:2018-02-11

Study on the Method of Sampling of Coagulated Particulate Matter (SO3) in Coal-Fired Power Plants
ZHANG Dejun,LIU Hanxiao,ZHAO Lin,YUAN Weifeng,FANG Xiaowei,XU Dongxu,LUO Jianyou.Study on the Method of Sampling of Coagulated Particulate Matter (SO3) in Coal-Fired Power Plants[J].Electric Power,2018,51(6):33-36,149.
Authors:ZHANG Dejun  LIU Hanxiao  ZHAO Lin  YUAN Weifeng  FANG Xiaowei  XU Dongxu  LUO Jianyou
Affiliation:1. Jilin Electric Power(JEP) Siping Thermal Power Generation Company, Jilin 136001, China; 2. Zhejiang Feida Environmental Science & Technology Co., Ltd., Zhuji 311800, China
Abstract:Regarding the existing drawbacks in the current sampling methods for condensable particulate matter (SO3), the traditional sampling units should be optimized to improve the collection efficiency of SO3. Several sampling schemes are compared respectively, including vertical and horizontal condenser plate, condensing coil and isopropyl alcohol absorption. The results show that for the capture effect of SO3 in flue gas, the outcome of the special vertical and horizontal condenser is almost the same, while the two-stage condensate coil exhibits the best performance, followed by the isopropanol absorption method, and the one-stage condensate coil the poorest. Based on this, the best capture scheme coupled two-stage of vertical condenser coil (65℃ constant temperature water bath) with 80% isopropyl alcohol absorption (0℃ ice bath) is put forward, and the onsite testing is carried out. The test results show that SO3 are captured by all of the above three units. However, the collection efficiency of the first stage condensate coil is the highest, then decreases in turn, and the SO3 capture ratio of the second stage condensate coil and isopropyl alcohol absorption unit is about 26%~40%.
Keywords:coal-fired power plant  ultra-low emission  SO3  SO3 collection  controlled condensation  isopropyl alcohol absorption  SO3 capture effect  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国电力》浏览原始摘要信息
点击此处可从《中国电力》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号