首页 | 官方网站   微博 | 高级检索  
     

双源CT前瞻性心电触发技术用于脑血管成像的初步研究
引用本文:薛跃君,钱农,邵燕惠,潘昌杰,荣伟良,许轶群.双源CT前瞻性心电触发技术用于脑血管成像的初步研究[J].中华放射医学与防护杂志,2012,32(3):326-328.
作者姓名:薛跃君  钱农  邵燕惠  潘昌杰  荣伟良  许轶群
作者单位:213003,江苏省常州市第二人民医院放射科
摘    要:目的 探讨双源Flash Spiral CT前瞻性心电触发序列(step-and-shoot,SAS)模式脑血管成像的图像质量及辐射剂量.方法 将43例临床怀疑脑血管性病变的患者,行前瞻性心电触发序列模式的脑血管造影术( SAS-CTA)扫描,采集期相:应用60% R-R间期的ECG演示模式,对SAS-CTA做图像后处理,分析评价图像质量评分、统计辐射剂量及优良率.结果 评价SAS-CTA,图像质量评分为4.72±0.50,优良率达97.7% (42/43),平均有效剂量为(0.216±0.01) mSv,SAS-CTA有效辐射剂量与双能量CTA( DE-CTA)比较降幅达到76.31%.结论 前瞻性心电触发序列模式应用于脑血管成像,可在保证图像质量的同时显著降低辐射剂量.

关 键 词:脑血管造影术  X射线计算机  辐射剂量  图像质量
收稿时间:2011/11/11 0:00:00

Cerebral angiography with prospective ECG triggering preliminary study of dual-source CT
XUE Yue-jun,QIAN Nong,SHAO Yan-hui,PAN Chang-jie,RONG Wei-liang and XU Yi-qun.Cerebral angiography with prospective ECG triggering preliminary study of dual-source CT[J].Chinese Journal of Radiological Medicine and Protection,2012,32(3):326-328.
Authors:XUE Yue-jun  QIAN Nong  SHAO Yan-hui  PAN Chang-jie  RONG Wei-liang and XU Yi-qun
Affiliation:Department of Radiology, Changzhou NO.2 People's Hospital, Changzhou 213003, China;Department of Radiology, Changzhou NO.2 People's Hospital, Changzhou 213003, China;Department of Radiology, Changzhou NO.2 People's Hospital, Changzhou 213003, China;Department of Radiology, Changzhou NO.2 People's Hospital, Changzhou 213003, China;Department of Radiology, Changzhou NO.2 People's Hospital, Changzhou 213003, China;Department of Radiology, Changzhou NO.2 People's Hospital, Changzhou 213003, China
Abstract:Objective To study the image quality and radiation dose in dual-source CT cerebral angiography with prospective ECG-triggered sequence mode (step-and-shoot, SAS).Methods A total of forty-three patients with clinically suspected cerebral vascular disease underwent cerebral CT angiography with prospective ECG-triggering (step-and-shoot,SAS). Data acquisition was at 60% R-R interval of the ECG presentation mode. The post-processing included maximum intensity projection (MIP), multiplanar reformation (MPR) and volume rendering (VR). The CTA image quality, radiation dose and rates of excellent images were evaluated.Results The CTA image quality score was 4.72±0.50 and 97.7% (42/43) patients had excellent CTA images. The average effective dose of SAS-CTA was (0.22±0.01) mSv,which was lower by 76.31% than that of DE-CTA.Conclusions Prospective ECG-triggering sequence could be used in cerebral angiography with a significant reduction in radiation dose and diagnostic image quality.
Keywords:Cerebral CTA  X-ray computed tomography  Radiation dose  Image quality
本文献已被 万方数据 等数据库收录!
点击此处可从《中华放射医学与防护杂志》浏览原始摘要信息
点击此处可从《中华放射医学与防护杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号