Institute of Chemistry, University of Genova, 1 J.F.Kennedy sq., 16129 Genova, Italy
Abstract:
The main properties of a protective coating for concrete and reinforced concrete structures are discussed. The importance of evaluating water and water-vapour permeability is highlighted. Two new methods for testing water and water-vapour permeability of protective coatings are presented. The reliability of these tests is studied. The proposed measurements could be seen as a preliminary screening test that would easily and economically evaluate coating performances.