首页 | 官方网站   微博 | 高级检索  
     

珠海发电厂电除尘装置磨损与腐蚀的分析处理
引用本文:吴咏梅.珠海发电厂电除尘装置磨损与腐蚀的分析处理[J].电站辅机,2006,27(2):40-42.
作者姓名:吴咏梅
作者单位:珠海发电厂,维修部,广东,珠海,519050
摘    要:文中主要介绍珠海发电厂电除尘装置在连续运行多年后,对电除尘阴极振打传动轴和轴瓦磨损严重的情况,及电除尘内部钢板腐蚀的情况,分析了具体原因,并提出解决办法。

关 键 词:热工学  电除尘装置  分析  磨损与腐蚀
文章编号:1672-0210(2006)02-0040-03
修稿时间:2005年10月8日

Analysis and Countermeasures of Electrostatic Precipitator Abrasion and Corrosion in Zhuhai Power Station
WU Yongmei.Analysis and Countermeasures of Electrostatic Precipitator Abrasion and Corrosion in Zhuhai Power Station[J].Power Station Auxiliary Equipment,2006,27(2):40-42.
Authors:WU Yongmei
Abstract:Serious abrasion of the transmission shaft and bush for cathode rapping of the electrostatic precipitator and the corrosion of the steel plates within the precipitator have been analysed and some ways to solve the problems have been put forward in the article based on the introduction to the precipitator in Zhuhai Power Station after continuous operation for many years.
Keywords:pyrology  electrostatic precipitator  analysis  abrasion and corrosion
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号