首页 | 官方网站   微博 | 高级检索  
     


A directional passive air sampler for monitoring polycyclic aromatic hydrocarbons (PAHs) in air mass
Authors:Tao S  Liu Y N  Lang C  Wang W T  Yuan H S  Zhang D Y  Qiu W X  Liu J M  Liu Z G  Liu S Z  Yi R  Ji M  Liu X X
Affiliation:Laboratory for Earth Surface Processes, College of Environmental Sciences, Peking University, Beijing 100871, China
Abstract:A passive air sampler was developed for collecting polycyclic aromatic hydrocarbons (PAHs) in air mass from various directions. The airflow velocity within the sampler was assessed for its responses to ambient wind speed and direction. The sampler was examined for trapped particles, evaluated quantitatively for influence of airflow velocity and temperature on PAH uptake, examined for PAH uptake kinetics, calibrated against active sampling, and finally tested in the field. The airflow volume passing the sampler was linearly proportional to ambient wind speed and sensitive to wind direction. The uptake rate for an individual PAH was a function of airflow velocity, temperature and the octanol-air partitioning coefficient of the PAH. For all PAHs with more than two rings, the passive sampler operated in a linear uptake phase for three weeks. Different PAH concentrations were obtained in air masses from different directions in the field test.
Keywords:Passive sampler  PAHs  Directional sampling
本文献已被 ScienceDirect PubMed 等数据库收录!