首页 | 官方网站   微博 | 高级检索  
     

邻面龋(牙合)翼片计算机自动分析诊断系统的建立和评价
引用本文:李涢,叶卫平,李玉晶,于洋.邻面龋(牙合)翼片计算机自动分析诊断系统的建立和评价[J].中华口腔医学杂志,2006,41(3):164-167.
作者姓名:李涢  叶卫平  李玉晶  于洋
作者单位:1. 100050,首都医科大学附属北京口腔医院牙体牙髓科
2. 北京师范大学信息科学学院
3. 100050,首都医科大学附属北京口腔医院口腔医学研究所
基金项目:首都医学发展科研基金资助项目(C03031101-171)志谢 首都医科大学附属北京口腔医院放射科栗文成、马兰、口控医学研究所葛立华老师
摘    要:目的 提高早期邻面龋的临床诊断水平,建立邻面龋X线图像的计算机自动分析诊断系统(CDS),并对诊断效果进行初步评价。方法 对含有早期邻面龋损、模拟天然牙列的95颗离体牙,进行平行投照的骀翼片检查并获得X线图像。通过对邻面龋损特征的分析比较,运用Matlab和VC语言,建立CDS。应用该系统自动检测牙齿邻面是否存在龋损及其深度。同时由8位检查者阅片。以组织学结果为金标准,评价诊断的准确度、敏感度、特异度及一致性等水平。结果 CDS诊断的敏感度为0.728,阅片法的平均敏感度为0.543。系统诊断深度与组织学深度的Pearson相关系数为0.722,优于肉眼阅片与组织学深度的相关系数(0.584)。系统重复检测的一致性较好。结论 CDS可以对邻面早期龋损进行自动诊断,其总体诊断水平优于肉眼阅片。

关 键 词:龋齿  诊断  计算机辅助  放射线摄影术  图像处理  计算机辅助
收稿时间:2005-12-19

Establishment and evaluation of a computer-based software system for detection of initial approximal caries
LI Yun,YE Wei-ping,LI Yu-jing,YU Yang.Establishment and evaluation of a computer-based software system for detection of initial approximal caries[J].Chinese Journal of Stomatology,2006,41(3):164-167.
Authors:LI Yun  YE Wei-ping  LI Yu-jing  YU Yang
Affiliation:Department of Operative and Endodontics, Faculty of Stomatology , Capital University of Medical Sciences, Beijing 100050, China
Abstract:OBJECTIVE: To establish and evaluate a computer-based software system (caries diagnosing system, CDS): CDS for better detection of initial approximal caries based on the performance of radiography. METHODS: A total of 190 approximal surfaces from 95 extracted posterior teeth were examined by bite-wing radiography. After analysing and extracting the approximal lesion's characteristics of X-ray performance, using Matlab and VC language, the CDS was established. Then the proximal surfaces of these teeth were detected automatically by CDS, and scored by naked eyes of 8 experienced dentists for the extent of lesions. The histological appearance of sectioned teeth was used as the gold standard to assess sensitivity, specificity, accuracy, and reproducibility. RESULTS: The sensitivity of CDS was 0.728, Pearson's correlation was 0.722, better than that of optic estimation. The reproducibility of CDS was good too. CONCLUSIONS: The CDS can report the lesion site and extension, its diagnostic level is better than that of optic estimation, it is an reasonably sensitive and accurate method for the detection of initial approximal caries in present clinic practice, and a tool of providing objective data.
Keywords:Dental caries  Diagnosis  computer-assisted  Radiography  Image processing  computer-assisted