首页 | 官方网站   微博 | 高级检索  
     

高效液相色谱-电感耦合等离子体质谱法测定海鱼中无机砷
引用本文:王甫,罗兰,黄承鹏,任燕.高效液相色谱-电感耦合等离子体质谱法测定海鱼中无机砷[J].预防医学情报杂志,2021(1).
作者姓名:王甫  罗兰  黄承鹏  任燕
作者单位:深圳市龙华区疾病预防控制中心公共卫生应急检测重点实验室
基金项目:深圳市龙华区科技计划重点实验室资助计划(项目编号:20160825A041006);深圳市“医疗卫生三名工程”(项目编号:SZSM201809085)。
摘    要:目的建立测定海鱼中无机砷含量的高效液相色谱-电感耦合等离子体质谱法。方法海鱼样品经稀硝酸超声热水浴提取后,AS7阴离子交换色谱柱分离,3.5 mmol/L(NH4)2CO3+1%甲醇与100 mmol/L(NH4)2CO3+1%甲醇流动相梯度洗脱,电感耦合等离子体质谱仪测定,以保留时间定性,外标法定量。结果在1~100μg/L的线性范围,6种砷形态化合物的回归方程均呈良好的线性关系,相关系数均优于0.9996,检出限为0.05~0.25μg/L,定量限为0.17~0.84μg/L,3个浓度加标回收率为88.5%~106.4%,相对标准偏差为2.5%~4.9%。结论本方法满足海鱼中无机砷含量的测定要求,提取快速,稳定,操作简单,检出限低,方法的重现性好,灵敏度高。

关 键 词:无机砷  高效液相色谱-电感耦合等离子体质谱  海鱼  形态分析

Determination of Inorganic Arsenic in Marine Fish by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
WANG Fu,LUO Lan,HUANG Chengpeng,REN Yan.Determination of Inorganic Arsenic in Marine Fish by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry[J].Journal of Preventive Medicine Information,2021(1).
Authors:WANG Fu  LUO Lan  HUANG Chengpeng  REN Yan
Affiliation:(Longhua District Center for Disease Control and Prevention,Shenzhen 518109,Guangdong Province,China)
Abstract:Objective To set up a method for the quantitative analysis of innorganic arsenic in marine fish by high performance liquid chromatography-inductively coupled plasma mass spectrometry.Methods The samples were extracted by ultrasonic hot water bath with dilute nitric acid and separated by AS7 anion exchange chromatography column,and the samples were eluted by 3.5 mmol/L(NH4)2CO3+1%methanoland 100 mmol/L(NH4)2CO3+1%methanol mobile phase gradient,and they were determined by inductively coupled plasma mass spectrometer,retention time for qualitative assay and external reference method were used for quantitative assay.Results Good linearities of the method were achieved over the concentration of 1~100μg/L of six compounds of arsenic form,with correlation coefficients above 0.9996.The limits of detection were0.05~0.25μg/L,and the limits of quantitation were 0.17~0.84μg/L.The relative standard deviation was 2.5%to 4.9%and recovery of 3 concentrations ranged from 88.5%to 106.4%.Conclusion The method meets the requirements of innorganic arsenic determination in marine fish.The extraction is rapid,stable,and the operation is simple.With low detection limit,it has good reproducibitity and high sensitivity.
Keywords:inorganic arsenic  high performance liquid chromatography-inductively coupled plasma mass spectrometry  marine fish  speciation analysis
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号