首页 | 官方网站   微博 | 高级检索  
     

4种蛋白质沉淀剂测定乳粉中非蛋白氮含量的效果
引用本文:漆亚乔,彭名军,黄秋婷,吴嘉文,苏燕瑜,刘冬豪,唐书泽.4种蛋白质沉淀剂测定乳粉中非蛋白氮含量的效果[J].食品安全质量检测技术,2020,11(16):5736-5741.
作者姓名:漆亚乔  彭名军  黄秋婷  吴嘉文  苏燕瑜  刘冬豪  唐书泽
作者单位:广州市食品检验所
基金项目:广州市科技计划项目(201707010372, 201704020024)
摘    要:目的 通过测定乳粉中非蛋白氮含量,比较四种蛋白质沉淀剂分离蛋白质和非蛋白含氮物质的效果。方法 样品加水溶解后分别用15 % 三氯乙酸溶液、丙酮、20 %乙酸铅溶液和3 % 草酸钾-7 % 磷酸氢二钠溶液、乙酸锌溶液和亚铁氰化钾溶液沉淀蛋白质,同时用三聚氰胺做加标回收,过滤后取滤液消化定氮。结果 三氯乙酸沉淀法计算非蛋白氮含量为0.2036%±0.0002%,相对标准偏差在四种方法中最小,为0.1023%,加标回收率为96.07±2.29%;丙酮沉淀法计算非蛋白氮含量为0.0981 %±0.0050 %,加标回收率在四种方法中最低,为50.56 %±7.90 %;乙酸铅沉淀法计算非蛋白氮含量为0.1372 %±0.0012 %,加标量为79.2mg三聚氰胺/10g样品时,乙酸铅沉淀法加标回收率比三氯乙酸沉淀法更稳定,为96.57%±1.07%;乙酸锌沉淀法计算非蛋白氮含量为0.3466 %±0.0100 %,加标回收率为86.81 %±2.87 %。结论 三氯乙酸沉淀法结果准确度和稳定性较其他三种方法更好,但受到加标量的影响。

关 键 词:乳粉  非蛋白氮  三氯乙酸  三聚氰胺  加标回收率
收稿时间:2020/5/20 0:00:00
修稿时间:2020/7/2 0:00:00

Determination of non-protein nitrogen in milk powder by four protein precipitants
QI Ya-Qiao,PENG Ming-Jun,HUANG Qiu-Ting,WU Jia-Wen,SU Yan-Yu,LIU Dong-Hao,TANG Shu-Ze.Determination of non-protein nitrogen in milk powder by four protein precipitants[J].Food Safety and Quality Detection Technology,2020,11(16):5736-5741.
Authors:QI Ya-Qiao  PENG Ming-Jun  HUANG Qiu-Ting  WU Jia-Wen  SU Yan-Yu  LIU Dong-Hao  TANG Shu-Ze
Affiliation:Guangzhou Inspection of Food Control
Abstract:Objective To determine the content of non-protein nitrogen in milk powder and compare the effects of four protein precipitants in separating protein and non-protein nitrogen. Methods Dissolve sample in water and make the protein be precipitated respectively with 15% trichloroacetic acid solution, acetone, 20% lead acetate solution and 3% potassium oxalate-7% disodium hydrogen phosphate solution, zinc acetate solution and potassium ferrocyanide solution. Meanwhile, melamine is added for spike recovery. The filtrate is taken to digest and determine nitrogen content. Results The non-protein nitrogen content gained by the trichloroacetic acid precipitation method was 0.2036% ± 0.0002%, with the smallest relative standard deviation, which was 0.1023%, among the four methods, and the recovery was 96.07 ± 2.29%; the non-protein nitrogen content applied with the acetone precipitation method was 0.0981% ± 0.0050%, accompanied with the lowest recovery, which is 50.56% ± 7.90%; the non-protein nitrogen content determined by the lead acetate precipitation method was 0.1372% ± 0.0012%. When the spike level was 79.2 mg melamine / 10g sample, the recovery of lead acetate precipitation method is more stable than that of trichloroacetic acid precipitation method, which could sustain 96.57% ± 1.07%; the non-protein nitrogen content acquired by zinc acetate precipitation method was 0.3466% ± 0.0100%, and the recovery was 86.81% ± 2.87%. Conclusion The accuracy and stability of the trichloroacetic acid precipitation method was better than other three methods, while it would be affected by the spiked levels.
Keywords:milk powder  non-protein nitrogen  trichloroacetic acid  melamine  spike recovery
点击此处可从《食品安全质量检测技术》浏览原始摘要信息
点击此处可从《食品安全质量检测技术》下载全文