首页 | 官方网站   微博 | 高级检索  
     

波形膨胀节对固定管板式换热器管板应力的影响
引用本文:袁强.波形膨胀节对固定管板式换热器管板应力的影响[J].化学工业与工程技术,2001,22(2):39-42.
作者姓名:袁强
作者单位:扬州化工学校,
摘    要:分析了波形膨胀节对固定管板式换热器管板应力的影响。计算了固定管板式换热器的轴向温差应力 ,说明设置膨胀节的必要性和合理性。提出了设置膨胀节需注意的一些问题。

关 键 词:波形膨胀节  换热器  管板  影响
文章编号:1006-7906(2001)02-0039-04
修稿时间:2000年11月10

Influence of waved expander on stress of fixed tube-plate exchanger
YUAN Qiang.Influence of waved expander on stress of fixed tube-plate exchanger[J].Journal of Chemical Industry & Engineering,2001,22(2):39-42.
Authors:YUAN Qiang
Affiliation:YUAN Qiang [
Abstract:The influence of waved expander on stress of fixed tube plate heat exchanger was analyzed and the stress caused from range of temperature on the axial section of fixed tube plate heat exchanger was calculated. The reasonableness and necessity for establishing expander was explained. The points of attention for establishing expander were put forward.
Keywords:Waved  expander  Heat  exchanger  Tube  plate  Influence