HPLC Method for the Determination of Tamsulosin Hydrochloride in Sustained Release Tablets
作者姓名:齐美玲  王鹏  耿颖姝  顾峻岭
作者单位:[1]DepartmentofChemistry,SchoolofScience,BeijingInstituteofTechnology,Beijing100081,China [2]SchoolofPharmaceuticalEngineering,ShenyangPharmaceuticalUniversity,Shenyang,Liaoning110015,China [3]ShenyangPharmtechInstituteofPharmaceuticals,Shenyang,Liaoning110015,China
摘    要:The development and validation of an isocratic high performance liquid chromatographic method is de-scribed for the determination of tamsulosin hydrochloride in sustained release tablets. The determination was per-formed on a Diamonsil BDS C18 column with a mobile phase consisting of a mixture of acetonitrile, methanol and 0.5% phosphoric acid solution (20:30:50, V/V/V) at a flow rate of 1.0 mL/min. UV detection was made at 274 nm. The linear range for tamsulosin hydrochloride was 0.81 - 8.10μg/mL. The mean recovery was 99.8%(SR = 0.7 %, n = 9), and the precision was found to be 0.45 % ( n = 9). The proposed method can be used for routine analysis of tamsulosin hydrochloride in sustained release tablets.

关 键 词:高效液相色谱分析  HPLC  药物分析  前列腺增生  治疗  缓释剂  盐酸坦索罗辛
收稿时间:2002/4/17 0:00:00

HPLC Method for the Determination of Tamsulosin Hydrochloride in Sustained Release Tablets
QI Mei ling,WANG Peng,GENG Ying shu and GU Jun ling.HPLC Method for the Determination of Tamsulosin Hydrochloride in Sustained Release Tablets[J].Journal of Beijing Institute of Technology,2003,12(2):194-197.
Authors:QI Mei ling  WANG Peng  GENG Ying shu and GU Jun ling
Affiliation:1. Department of Chemistry, School of Science, Beijing Institute of Technology, Beijing 100081, China
2. School of Pharmaceutical Engineering, Shenyang Pharmaceutical University, Shenyang, Liaoning 110015, China
3. Shenyang Pharmtech Institute of Pharmaceuticals, Shenyang, Liaoning 110015, China
Abstract:The development and validation of an isocratic high performance liquid chromatographic method is described for the determination of tamsulosin hydrochloride in sustained release tablets. The determination was performed on a Diamonsil BDS C18 column with a mobile phase consisting of a mixture of acetonitrile, methanol and 0.5% phosphoric acid solution (20∶30∶50,V/V/V) at a flow rate of 1.0 mL/min. UV detection was made at 274 nm. The linear range for tamsulosin hydrochloride was 0.81-8.10 μg/mL. The mean recovery was 99.8% (SR=0.7%, n=9), and the precision was found to be 0.45% (n=9). The proposed method can be used for routine analysis of tamsulosin hydrochloride in sustained release tablets.
Keywords:HPLC  tamsulosin hydrochloride  sustained release tablets
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《北京理工大学学报(英文版)》浏览原始摘要信息
点击此处可从《北京理工大学学报(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号