首页 | 官方网站   微博 | 高级检索  
     


Benchmark analysis of main circulation pump trip events at the Ignalina NPP using RELAP5 code
Authors:A Kaliatka  E Uspuras  
Affiliation:Laboratory of Nuclear Installation Safety, Lithuanian Energy Institute, 3 Breslaujos, 3035 Kaunas, Lithuania
Abstract:The state-of-the-art code RELAP5/MOD3 was originally designed for PWRs. Because of unique RBMK designs the application of this code to RBMK-1500 encountered several problems. A successful best estimate RELAP5 model of the Ignalina NPP has been developed. This model includes the reactor main circulation circuit (MCC) and reactor control and protection system required for this kind of transient analysis. Benchmark analysis of all operating main circulation pump (MCP) trip events was performed. During the analysis the characteristics of isolation control valves and MCP throttling regulating valves were established. Comparison of calculated and measured parameters was also used to establish realistic resistances of different MCC components and realistic behaviour of the controllers of the reactor systems. Calculations performed with the RELAP5 model, which includes these modifications, compare favourably with plant data.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23