2. 山西电力科学研究院,山西,太原,030001
摘    要:分析影响再热汽温的因素,对实际运行工况所采取的调节手段和试验数据进行比较、探讨,从而使再热汽温的变化控制在最小范围内,以满足整台机组的安全、稳定、经济运行。

关 键 词:火电机组  再热汽温  调节
文章编号:1671-0320(2001)06-0026-03
修稿时间:2001年6月28日

Adjustment on Reheating Steam Temperature of 300 MW Thermal Power Plant
WANG Wen biao ,LI Jin ping ,YOU Wen ming.Adjustment on Reheating Steam Temperature of 300 MW Thermal Power Plant[J].Shanxi Electric Power,2001(6):26-28.
Authors:WANG Wen biao  LI Jin ping  YOU Wen ming
Affiliation:WANG Wen biao 1,LI Jin ping 1,YOU Wen ming 2
Abstract:Analysis are made on factors influencing reheating temperature.comparation and discussion are adopted through adjusting means and testing data,the changing of reheating temperature is controlled to the minimum range,so as to content with the safty,stable and economical operating of the unit.