首页 | 官方网站   微博 | 高级检索  
     

600MW机组锅炉给水前置泵改进
引用本文:李奎,张京文,王义天,邹节廉.600MW机组锅炉给水前置泵改进[J].华北电力技术,2008(4):32-35.
作者姓名:李奎  张京文  王义天  邹节廉
作者单位:1. 国电电力大同发电有限责任公司,山西大同,1037043
2. 天津市智新源科技有限公司,天津,300204
摘    要:针对大同发电公司600 MW机组给水前置泵投产1年后故障频发,运行稳定性差的问题,进行测试分析,找出问题根源,并采取了一系列简单使用、投资少、具有较好适用性的改进措施,使问题得以解决。

关 键 词:锅炉  给水泵  前置泵
文章编号:1003-9171(2008)04-0032-04
修稿时间:2008年1月17日

Improvement of Boost Pump of Feedwater for 600 MW Unit
Li Kui,Zhang Jing-wen,Wang Yi-tian,Zou Jie-lian.Improvement of Boost Pump of Feedwater for 600 MW Unit[J].North China Electric Power,2008(4):32-35.
Authors:Li Kui  Zhang Jing-wen  Wang Yi-tian  Zou Jie-lian
Abstract:The feed boost pump for 600MW unit was put into service 1 year ago in Datong Power Generation Co.,Ltd.,failures and poor operation stability frequently occurred.After some tests and analysis,the root causes were found out,and a series of simple,less cost and appropriate improvement measures were adopted,the problems were solved eventually.
Keywords:boiler  feedwater pump  boost pump
本文献已被 CNKI 维普 万方数据 等数据库收录!