首页 | 官方网站   微博 | 高级检索  
     


Impact of simethicone on bowel cleansing during colonoscopy in Chinese patients
Authors:Hu Zhang  Jing Liu  Song-Lin Ma  Man-Lin Huang  Yan Fan  Min Song  Jing Yang  Xiao-Xia Zhang  Qi-Long Song  Jing Gong  Ping-Xiao Huang  Heng Zhang
Affiliation:Hu Zhang, Jing Liu, Song-Lin Ma, Man-Lin Huang, Yan Fan, Min Song, Jing Yang, Xiao-Xia Zhang, Qi-Long Song, Jing Gong, Ping-Xiao Huang, Heng Zhang, Department of Gastroenterology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430014, Hubei Province, ChinaHu Zhang, Department of Gastroenterology, The Eighth Hospital of Wuhan, Wuhan 430014, Hubei Province, China
Abstract:BACKGROUNDFour-liter polyethylene glycol (PEG) solutions are effective for bowel cleansing, but their large volume might hinder patient compliance. Due to the unique features of Asians, 4 L PEG might be a suboptimal bowel preparation in predominantly ethnically Asian countries. In view of this, a balance should be achieved between the volume and effectiveness. The ideal bowel cleansing regimen for a colonoscopy has yet to be determined in a Chinese population.AIMTo compare the cleansing efficacy of 3 L PEG plus simethicone with 4 L PEG.METHODSA total of 291 patients were randomly allocated to two groups: Group 1 (n = 145) received 4 L split-dose PEG (4-P); group 2 (n = 146) received 3 L split-dose PEG plus simethicone (3-PS). Bowel-cleansing efficacy was evaluated by endoscopists using the Boston bowel preparation scale (BBPS) and the bubbles score.RESULTSAlthough there were no significant differences in the total BBPS score or the adequate rate of bowel preparation between the two groups, the BBPS score of the right-side colon was significantly higher in the 3-SP group (2.37 ± 0.54 vs 2.21 ± 0.78; P = 0.04). Moreover, the use of simethicone significantly reduced bubbles in all colon segments (P < 0.001). The mean withdrawal time was significantly shorter in the 3-PS group (8.8 ± 3.4 vs 9.6 ± 2.3; P = 0.02). Furthermore, significantly more proximal adenomas were detected in the 3-PS group (53.6% vs 45.7%; P = 0.03). In addition, the proportions of patients with nausea and bloating were significantly lower in the 3-SP group (P < 0.01 for both). More patients in the 3-PS group expressed willingness to repeat the bowel preparation (87.7% vs 76.6%, P = 0.01).CONCLUSIONThree-liter PEG shows satisfactory bowel cleansing despite the decrease in dosage, and addition of simethicone with better bubble elimination and enhanced patient acceptance offers excellent potential impact on the detection of proximal adenomas in Chinese patients.
Keywords:Polyethylene glycol  Simethicone  Colonoscopy  Bowel preparation  Cleansing efficacy
本文献已被 维普 等数据库收录!
点击此处可从《》浏览原始摘要信息
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号