Characterization of flow homogeneity downstream of a slotted orifice plate in a two-phase flow using electrical resistance tomography
Affiliation:1. Department of Physics, Faculty of Mathematics and Natural Sciences, Bogor Agricultural University, Kampus IPB Darmaga, Bogor, West Java 16680, Indonesia;2. Department of Mechanical and Biosystem Engineering, Faculty of Agricultural Technology, Bogor Agricultural University, Kampus IPB Darmaga, Bogor, West Java 16680, Indonesia;3. Department of Physics, Graduate School of Nanoscience & Technology (WCU), KAIST Center for LED Research, and KI for the NanoCentury, KAIST, Daejeon 305-701, Republic of Korea;4. Department of Civil and Environmental Engineering, Faculty of Agricultural Technology, Bogor Agricultural University, Kampus IPB Darmaga, Bogor, West Java 16680, Indonesia;1. Dorodnicyn Computing Centre of Russian Academy of Sciences, Moscow, Russia;2. Bauman Moscow State Technical University, Moscow, Russia;3. Moscow Institute of Physics and Technology, Moscow, Russia
Abstract:Two-phase flows are complex and unpredictable in nature, commonly encountered in a majority of fluid transport systems. The accurate measurement of two-phase flow is critical for a wide range of applications from wet stream to multiphase flows. There are different methods to meter two-phase flow in various industries. One approach is to produce a flow meter that does not require the individual flow components to be separated and measured separately. This goal can be met if a homogenized mixture is produced which can be measured by a standard single phase flow meter. The slotted orifice plate was invented as a flow meter for single phase flows, it is independent upon upstream flow conditions. Slotted orifice plate flow meter's utilization in two-phase flow revealed that it is highly capable of working as a flow conditioner transforming most of the multiphase flow regimes into a fairly uniform mixture. This study measures how the relative homogeneity of an air/water mixture varies downstream of the slotted plate in a horizontal pipe for various upstream conditions including elongated bubble and slug flow regimes using electrical resistance tomography (ERT). According to this study, the optimal location with a maximum homogeneity was determined to be between 1.5 and 2.5 pipe diameters downstream of the slotted orifice plate. This indicates that placing a slotted orifice plate at the obtained distance upstream of another flow meter such as a venturi coupled with a density measuring device like a radiation based densitometer or an electrical impedance device will help in obtaining accurate multiphase flow rate measurement.
Keywords:Electrical resistance tomography ERT  Slotted orifice plate  Flow homogeneity  Two phase flow
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号