首页 | 官方网站   微博 | 高级检索  
     

多接入点分布式光伏发电系统与配电网交互影响研究
引用本文:崔红芬,汪春,叶季蕾,薛金花,杨波.多接入点分布式光伏发电系统与配电网交互影响研究[J].电力系统保护与控制,2015,43(10):91-97.
作者姓名:崔红芬  汪春  叶季蕾  薛金花  杨波
作者单位:中国电力科学研究院,江苏 南京 210003;中国电力科学研究院,江苏 南京 210003;中国电力科学研究院,江苏 南京 210003;中国电力科学研究院,江苏 南京 210003;中国电力科学研究院,江苏 南京 210003
基金项目:国家电网公司基础性前瞻性科技项目(XT71-14-004)
摘    要:针对分布式光伏发电的谐波源特性和功率波动性,对分布式光伏接入对配电网谐波、电压波动和闪变的影响进行了分析,并分析了背景电能质量问题对光伏并网点电能质量的影响。同时在DIg SILENT/Power Factory仿真平台上搭建了国际大电网会议(CIGRE)认为适合进行分布式发电接入配电网特性研究的典型配电网络结构,并根据IEC 61400-4-15标准在该平台上搭建了IEC电压闪变仪,对含多接入点分布式光伏发电的配电网的谐波传输和放大特性、电压波动和闪变的影响和评估进行了仿真分析。仿真结果表明,含多接入点分布式光伏的配电网中谐波传输和放大特性非常复杂;配电网各母线节点的电压波动和闪变值的大小与该母线节点的短路容量和功率波动密切相关。

关 键 词:分布式光伏  谐波  电压波动与闪变  电能质量
收稿时间:2014/3/19 0:00:00
修稿时间:2014/12/1 0:00:00

Research of interaction of distributed PV system with multiple access points and distribution network
CUI Hongfen,WANG Chun,YE Jilei,XUE Jinhua and YANG Bo.Research of interaction of distributed PV system with multiple access points and distribution network[J].Power System Protection and Control,2015,43(10):91-97.
Authors:CUI Hongfen  WANG Chun  YE Jilei  XUE Jinhua and YANG Bo
Affiliation:China Electric Power Research Institute, Nanjing 210003, China;China Electric Power Research Institute, Nanjing 210003, China;China Electric Power Research Institute, Nanjing 210003, China;China Electric Power Research Institute, Nanjing 210003, China;China Electric Power Research Institute, Nanjing 210003, China
Abstract:For harmonic source characteristics and power volatility of distributed PV, the effects of PV connecting to grid on harmonics, voltage fluctuation and flicker of distribution network are analyzed. And the impact of background power quality of distribution network on the power quality of PV connecting points is also analyzed. Meanwhile, a typical distribution network is built on DIgSILENT / PowerFactory simulation platform, which is considered to be suitable for study of PV grid-connecting characteristics by CIGRE. According to IEC 61400-4-15 standard, the IEC voltage flicker meter is also built on the platform. And then the harmonic transmission and amplification characteristics, the impact and assessment of voltage fluctuation and flicker are simulated. The simulation results show that harmonic transmission and amplification characteristics are complex in distribution network with multiple distributed PV. Additionally, the value of voltage fluctuation and flicker at each bus node is closely related to the short-circuit capacity of the bus node and power fluctuation of distributed PV.
Keywords:distributed PV  harmonics  voltage fluctuation and flicker  power quality
本文献已被 CNKI 等数据库收录!
点击此处可从《电力系统保护与控制》浏览原始摘要信息
点击此处可从《电力系统保护与控制》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23