首页 | 官方网站   微博 | 高级检索  
     

炭粒床高效工业除尘装置的设计与开发
引用本文:张济宇, ,旷戈, ,林诚.炭粒床高效工业除尘装置的设计与开发[J].中国化学工程学报,2004,12(3):395-400.
作者姓名:张济宇     旷戈     林诚
作者单位:InstituteofChemicalEngineeringandTechnology,FuzhouUniversity,Fuzhou350002,"China
基金项目:the Fujian Provincial Science and Technology Council Grant (No. 2001H043).
摘    要:The new dust removal technical route using the carbon-granular bed filter, packed of carbon particles with appropriate grade derive from an online-process vibration sieve, to replace the traditional baggy filter had been developed successfully for capturing the micro-carbon dusts produced from pulverization of petroleum coke,and the green close loop of carbon materials is thus completed in the combined pulverizing and classifying system and pulverized carbon dust removal process. The high dust removal efficiency greater than 99%, low outlet dust concentration less than 100 mg-m-S, low pressure drop through dust filtration chamber less than 980 Pa, simple and easy design, and flexible and stable operation were achieved also with the carbon-granular bed filter in both bench and industrial scale operations.

关 键 词:压力降  除尘设备  滤波器  CGBF    TBF
修稿时间: 

Design and Development of a High Efficiency CarbonGranular Bed Filter in Industrial Scale
ZHANG Jiyu,KUANG Ge,LIN Cheng.Design and Development of a High Efficiency CarbonGranular Bed Filter in Industrial Scale[J].Chinese Journal of Chemical Engineering,2004,12(3):395-400.
Authors:ZHANG Jiyu  KUANG Ge  LIN Cheng
Affiliation:Institute of Chemical Engineering and Technology, Fuzhou University, Fuzhou 350002, China
Abstract:The new dust removal technical route using the carbon-granular bed filter, packed of carbon particles with appropriate grade derive from an online-process vibration sieve, to replace the traditional baggy filter had been developed successfully for capturing the micro-carbon dusts produced from pulverization of petroleum coke,and the green close loop of carbon materials is thus completed in the combined pulverizing and classifying system and pulverized carbon dust removal process. The high dust removal efficiency greater than 99%, low outlet dust concentration less than 100 mg-m-S, low pressure drop through dust filtration chamber less than 980 Pa, simple and easy design, and flexible and stable operation were achieved also with the carbon-granular bed filter in both bench and industrial scale operations.
Keywords:carbon-granular bed  dust removal  outlet dust concentration  pressure drop
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《中国化学工程学报》浏览原始摘要信息
点击此处可从《中国化学工程学报》下载全文