首页 | 官方网站   微博 | 高级检索  
     


Recent progress on the J-TEXT three-wave polarimeter-interferometer
Affiliation:1. International Joint Research Laboratory of Magnetic Confinement Fusion and Plasma Physics, State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, People's Republic of China 2. United Kingdom Atomic Energy Authority, Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB, United Kingdom 
Abstract:The J-TEXT three-wave polarimeter-interferometer system (POLARIS), which measures time-space distribution of electron density and current density, has been optimized with both the optical system and the equilibrium reconstruction method. The phase resolution of a Faraday rotation angle has been improved from 0.1 to 0.06 degree in chords from –0.18 to 0.18 m (plasma minor radius), and the sawtooth oscillation behavior has been detected by Faraday rotation angle measurement. By combining the POLARIS measured data and the equilibrium and fitting code (EFIT), an upgraded equilibrium reconstruction method has been developed, which provides a more accurate temporal and spatial distribution of current density and electron density. By means of the optimized POLARIS and improved equilibrium reconstruction, variations of profiles with increasing density have been carried out, under both Ohmic and electron cyclotron resonance heating discharges.
Keywords:current density profile  EFIT  polarimeters  