首页 | 官方网站   微博 | 高级检索  
     

重油隧道窑的红外温度测量
引用本文:姜世昌,陈出新.重油隧道窑的红外温度测量[J].红外技术,1997,19(6):29-32.
作者姓名:姜世昌  陈出新
作者单位:上海工业自动化仪表研究所
摘    要:在分析重油隧道窑工况的基础上,分析了窑内烟气、燃烧物发射率、窑墙效应、环境温度对红外测温的影响以及热电偶测温的缺点,采取了相应的措施。利用中国发现专科实现了传感器输出信号的一致性。给出了传感器在重滑隧道窑现场使用2.5年后的复校数据。最后,估算出了用红外温度计替代热电偶测窑温产生的经济效益。

关 键 词:红外温度测量  重油隧道窑  热电偶  耐火材料

Temperature Measurement in Crude Oil Tunnel Kiln
Jiang Shichang,Chen Chuxin.Temperature Measurement in Crude Oil Tunnel Kiln[J].Infrared Technology,1997,19(6):29-32.
Authors:Jiang Shichang  Chen Chuxin
Abstract:Infrared temperature measurement in tunnel kiln burned with crude oil has been made.The burning frame,emissivity of the material to be burned,kiln wall,enviornment temperature and the effectiveness of the thermocouple temperature measurement have been analysed,appropriate measures have been taken.The uniformity of sensors has been improved with a patented method.The tested data of the sensors working for 2.5 years have been listed.The economical profits using infrared thermometers instead of thermocouples in temperature measurement are estimated.
Keywords:Infrared temperature measurement  Tunnel kiln  Influence element
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号