首页 | 官方网站   微博 | 高级检索  
     

基于EJ299-33A探测器的核材料时间关联测量系统的时间分辨
引用本文:宋志浩,李永明,阮念寿,徐文韬,田立朝,王尚武.基于EJ299-33A探测器的核材料时间关联测量系统的时间分辨[J].原子能科学技术,2018,52(11):2061-2066.
作者姓名:宋志浩  李永明  阮念寿  徐文韬  田立朝  王尚武
作者单位:1.国防科技大学 文理学院,湖南 长沙410000;2.表面物理与化学重点实验室,四川 绵阳621907;3.中国工程物理研究院 材料研究所,四川 绵阳621907
摘    要:n-γ的时间关联测量可提取核材料的质量、增殖因数,其中时间分辨是表征关联精度的1个重要指标。本文基于数字化数据获取与处理方法,对具有n-γ甄别能力的塑料闪烁体EJ299-33A探测器组成的核材料时间关联测量系统的时间分辨进行研究,采用60Co与22Na γ源进行了对比测量,分析了源对本征时间分辨的影响,进一步通过离线的条件加载反演,给出时间分辨的等效电子能量阈值依赖关系。通过对252Cf自发裂变时间关联谱的测量和解耦,讨论了时间分辨对不同符合事件的影响。结果表明:系统时间分辨随阈值增加而减少,在阈值为230 keVee时采用60Co测量的结果约为560 ps,可满足核材料快时间符合测量的精度要求,而在相同条件下,由于正电子湮没位置的不确定性和延迟符合的影响,22Na源测量的时间分辨展宽至816 ps;裂变事件时间关联测量中n-n符合受时间分辨的相对影响小于γ-γ符合。

关 键 词:核材料测量    EJ299-33A探测器    时间分辨    阈值依赖

Time Resolution of Nuclear Material Time Cross-correlation Measurement System Based on EJ299-33A Detector
SONG Zhihao,LI Yongming,RUAN Nianshou,XU Wentao,TIAN Lichao,WANG Shangwu.Time Resolution of Nuclear Material Time Cross-correlation Measurement System Based on EJ299-33A Detector[J].Atomic Energy Science and Technology,2018,52(11):2061-2066.
Authors:SONG Zhihao  LI Yongming  RUAN Nianshou  XU Wentao  TIAN Lichao  WANG Shangwu
Affiliation:1.College of Liberal Arts and Sciences, National University of Defense Technology, Changsha 410000, China;2.Key Laboratory for Surface Physics and Chemistry, Mianyang 621907, China;3.Institute of Materials, China Academy of Engineering Physics, Mianyang 621907, China
Abstract:The neutron and gamma time cross-correlation measurement could extract mass and multiplication coefficient of nuclear material, in which time resolution is an important parameter to characterize the correlation precision. Based on the means of digital data acquisition and processing, the time resolution was assessed for nuclear material time cross-correlation measurement system, which consisted of two novel plastic scintillator EJ299-33A detectors with particle discrimination capability, and the effect of the source was analyzed by comparing the 60Co and 22Na measurements. Furthermore, the equivalent electron energy threshold dependence of time resolution was given by off-line inversion, and the influences on different coincidence events were discussed by decoupling of the time correlated spectrum of 252Cf. The results show that the time resolution of system decreases with the increase of equivalent threshold, and the time resolution of 560 ps was obtained at the threshold of 230 keVee by 60Co measurement, which could meet the accuracy requirement of the nuclear material time cross-correlation measurements. Nevertheless, the result acquired by 22Na measurement is widened to about 816 ps at the same threshold due to the uncertainty of positron annihilation position and the delayed coincidence. In the fission events correlated measurement, the relative influence of time resolution on n-n coincidences is smaller than that on γ-γ coincidences.
Keywords:nuclear material measurement  EJ299-33A detector  time resolution  threshold dependence
本文献已被 CNKI 等数据库收录!
点击此处可从《原子能科学技术》浏览原始摘要信息
点击此处可从《原子能科学技术》下载全文