首页 | 官方网站   微博 | 高级检索  
     

加工海洋高酸原油常减顶冷却器腐蚀原因分析
引用本文:薛光亭,黄国都.加工海洋高酸原油常减顶冷却器腐蚀原因分析[J].石油化工腐蚀与防护,2014(4):52-56.
作者姓名:薛光亭  黄国都
作者单位:中海油(青岛)重质油加工工程技术研究中心有限公司,山东青岛266500
摘    要:阐述了加工海洋高酸原油的常减压蒸馏装置一脱三注工艺防腐蚀措施的运行情况以及常减顶冷却器的腐蚀情况,对引起常压塔顶和减压塔顶冷凝冷却器的腐蚀原因进行了分析,认为腐蚀的主要原因是高酸原油电脱盐后盐含量高,造成塔顶氯离子含量高,提出了减轻腐蚀的措施。

关 键 词:高酸原油  常减顶冷却器  腐蚀

Analysis of Corrosion Causes of Overhead Coolers of Atmospheric-vacuum Distillation Towers in Processing Marine High-TAN Crudes Oil
Xue Guangting,Huang Guodu.Analysis of Corrosion Causes of Overhead Coolers of Atmospheric-vacuum Distillation Towers in Processing Marine High-TAN Crudes Oil[J].Petrochemical Corrosion and Protection,2014(4):52-56.
Authors:Xue Guangting  Huang Guodu
Affiliation:(CNOOC Qingdao Heavy Oil Process Engineering Technology Research Center Co. ,Ltd, Qingdao, Shandong 266500)
Abstract:The corrosion protection by desahing and injection of water, corrosion inhibitor and fouling inhibitor for atmospheric - vacuum distillation unit processing marine high - TAN crude oils and the corrosion of overhead coolers of atmospheric and vacuun distillation towers are elaborated. The corrosion causes of tower overhead coolers are studied. The analysis concluded that th, main culprits of corrosion are the high salt content in the desalted high - TAN crude oil, which results in higher chorine ions in the overhead. Corresponding measures have been recommended for the mitigation of corrosion.
Keywords:high - TAN crude oil  overhead cooler of atmospheric - vacuum distillation tower  corrosion
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23