摘    要:分析CNG加气站总图设计中防火间距的重要性、爆炸危险区域的概念及作用,对现行国家标准GB 50156—2012《汽车加油加气站设计与施工规范》中站内设施的防火间距与爆炸危险区域的相互关系进行探讨,提出CNG加气站总图设计中确定设施之间距离时应考虑防火间距、爆炸危险区域两个因素。

关 键 词:防火间距  爆炸危险区域  CNG加气站

Discussion on Fire Spacing for Facilities and Explosion Hazardous Area in CNG Filling Station
LIU Qiang,ZHU Wanmei.Discussion on Fire Spacing for Facilities and Explosion Hazardous Area in CNG Filling Station[J].Gas & Heat,2014,34(11):13-15.
Authors:LIU Qiang  ZHU Wanmei
Affiliation:LIU Qiang,ZHU Wanmei
Abstract:The importance of fire spacing aswell as the concept and function of explosion hazardousarea in general design of CNG filling station are ana-lyzed. The relationship between the fire spacing andthe explosion hazardous area in the current nationalstandard Code for Design and Construction of Automo-bile Gasoline and Gas Filling Station (GB 50156 -2012) is discussed. It is put forward that the two fac-tors namely fire spacing and explosion hazardous areashould be taken into account in determination of thedistance between facilities in general design of CNGfilling station.
Keywords:fire spacing  explosion hazardousarea  CNG filling station