首页 | 官方网站   微博 | 高级检索  
     

采用SrCl2-NH4Cl-NH3工质对的二级吸附式冷冻循环性能
引用本文:罗伟莉,王健,王丽伟,江龙,金哲权,王如竹.采用SrCl2-NH4Cl-NH3工质对的二级吸附式冷冻循环性能[J].化工学报,2012,63(4):1004-1010.
作者姓名:罗伟莉  王健  王丽伟  江龙  金哲权  王如竹
作者单位:上海交通大学制冷与低温工程研究所,上海 200240
基金项目:国家自然科学基金项目(50806043)~~
摘    要:吸附式制冷是一种绿色环保节能的制冷技术,在低于100℃的低品位热能如废热能、太阳能等的利用方面具有广阔的发展前景。为了能够利用这部分的能源,提出了由吸附制冷过程与再吸附过程组成的二级吸附式制冷循环。采用SrCl2-NH4Cl-NH3作为工质对,测试不同蒸发温度与冷却温度下吸附剂的吸附与解吸性能。实验测试结果表明:当热源温度为70℃时,二级吸附式制冷也能够实现-25℃下的冷量输出。在测试工况下,氯化锶的最大吸附量达到了理论吸附量的94%。80℃热源、25℃冷源以及-25℃制冷条件下二级吸附式制冷循环的COP和SCP达到了0.250与160 W·kg-1。这个数值与CaCl2-BaCl2-NH3两级冷冻在85℃驱动热源以及同等的冷源与制冷温度条件下的数据相对比,驱动热源需求降低了5℃,COP提高了4%,SCP提高了10%以上。

关 键 词:吸附式制冷  二级吸附  低温热源  制冷性能  
收稿时间:2011-07-18
修稿时间:2012-01-06

Performance of two-stage adsorption freezing cycle with SrCl2-NH4Cl-NH3
LUO Weili , WANG Jian , WANG Liwei , JIANG Long , JIN Zhequan , WANG Ruzhu.Performance of two-stage adsorption freezing cycle with SrCl2-NH4Cl-NH3[J].Journal of Chemical Industry and Engineering(China),2012,63(4):1004-1010.
Authors:LUO Weili  WANG Jian  WANG Liwei  JIANG Long  JIN Zhequan  WANG Ruzhu
Affiliation:Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai  200240, China
Abstract:Adsorption refrigeration is an environmental benign and energy saving refrigeration technology and has a great potential for the utilization of low-grade energy,such as solar energy and industrial waste heat below 100℃.For efficient utilization of these low-temperature heat sources,a two-stage adsorption refrigeration cycle was proposed based on the adsorption refrigeration process and resorption process.Refrigeration performance of the working pair of SrCl2-NH4Cl-NH3 was tested at different evaporating and condensing temperatures.The results show that the two-stage adsorption refrigeration cycle can give the cooling output with the temperature of-25℃ when the temperature of the heat source is 70℃.The adsorption quantity of strontium chloride is 94% of the theoretical value.Under the condition of 80℃ heat source,25℃ cooling source,and-25℃ refrigerating temperature,the COP and SCP are 0.250 and 160 W·kg-1,respectively.At the same cooling and refrigerating temperatures,compared with the working pair of CaCl2-BaCl2-NH3 with the heat source temperature of 85℃,the heat source temperature in this study decreases 5℃,and COP and SCP increase by 4% and 10%,respectively.
Keywords:adsorption refrigeration  two-stage adsorption  low-temperature heat source  refrigeration performance