用标准表法检定特大口径流量计时温度影响的分析
引用本文:赵雨斌.用标准表法检定特大口径流量计时温度影响的分析[J].上海理工大学学报,2000,22(1):53-56.
作者姓名:赵雨斌
作者单位:上海理工大学光学与电子信息工程学院!上海200093
摘    要:特大口径电磁流量计是一种新型的大口径水计量仪表,它的实流检定是制约其自身发展的关键因素.本文讨论了用标准表法检定特大口径流量计的原理,分析了温度对标准表法流量检定装置的影响,提出了误差修正方法和对检定装置设计的要求.

关 键 词:误差修正  标准表法  流量计  温度  检定

The analysis of temperature influence on verification of super large diameter flowmeter with master meter method
ZHAO Yu-bin,JU Zi-pei.The analysis of temperature influence on verification of super large diameter flowmeter with master meter method[J].Journal of University of Shanghai For Science and Technology,2000,22(1):53-56.
Authors:ZHAO Yu-bin  JU Zi-pei
Abstract:Super-large diameter electromagnetic flowmeter is one of the new types of water flowmeter. Howerer its real-flow verification is the key obstacle to its development. In the thesis the theory of master meter method for verification of super-large diameter flowmeter is discussed and the temperature influence on the calibration rig with method of master meter is analysed. It is tried to find the method of error correction and to propose design requirements.
Keywords:verification  temperature influence  error correction  master meter method  