首页 | 官方网站   微博 | 高级检索  
     

高压板翅式换热器氧通道堵塞原因分析和处理
引用本文:庄光山,马高永.高压板翅式换热器氧通道堵塞原因分析和处理[J].深冷技术,2011(1):1-4.
作者姓名:庄光山  马高永
作者单位:山东华鲁恒升化工股份有限公司;
摘    要:华鲁恒升KDON-48000/45500型空分设备按计划停车检修再开车后,出现了高压板翅式换热器氧通道因珠光砂堵塞而阻力上升故障。在设备停车后对高压板翅式换热器氧通道进行反吹以消除阻力,使高压板翅式换热器正常运行。文章简介了高压板翅式换热器流程、故障经过以及故障带来的负面影响,叙述了处理措施和取得的效果。

关 键 词:大型空分设备  高压板翅式换热器  珠光砂  堵塞  吹除

Analysis the causes for and treatment of blocking of oxygen passage of high-pressure plate-fin heat exchanger
Zhuang Guangshan,Ma Gaoyong.Analysis the causes for and treatment of blocking of oxygen passage of high-pressure plate-fin heat exchanger[J].Cryogenic Technology,2011(1):1-4.
Authors:Zhuang Guangshan  Ma Gaoyong
Affiliation:Zhuang Guangshan,Ma Gaoyong(Shandong Hualu-Hengsheng Chemical Co.,Ltd.,Dezhou 253024,Shandong,P.R.China)
Abstract:At re-start of Hualu-Hengsheng Model KDON-48000/45500 air separation plant after planned shutdown and repair,the drag increases due to blocking of the oxygen passage of high-pressure plate-fin heat exchanger by pearlite.After shutdown,the high-pressure plate-fin heat exchanger is recovered to normal run after elimination of the drag through back-blowing of its oxygen passage.Here,the process of high-pressure plate-fin heat exchanger,the particulars of trouble and the trouble-generated negative impact are br...
Keywords:Large-sized air separation plant  High-pressure plate-fin heat exchanger  Pearlite  Blocking  Blowing out  