首页 | 官方网站   微博 | 高级检索  
     

高压绕管式换热器中换热管漏气后的返修
引用本文:张庆生.高压绕管式换热器中换热管漏气后的返修[J].深冷技术,2011(1):23-28.
作者姓名:张庆生
作者单位:开封东京空分集团有限公司;
摘    要:从某套空分设备上卸下的DR87XX型高压绕管式换热器的换热管胀接部分焊缝出现漏气现象,原因是胀接压力过大。制定了详尽的返修方案,具体实施后高压绕管式换热器恢复正常运行。文章简介了DR87XX型高压绕管式换热器中管板与换热管的"胀接+强度焊"模式,详细叙述了返修前的胀接试验、检验和返修工艺过程,最后总结了返修中的注意事项。

关 键 词:高压绕管式换热器  换热管  返修  胀接  强度焊  胀接试验

Repair after leakage of heat exchange pipe in high-pressure spiral tube heat exchanger
Zhang Qingsheng.Repair after leakage of heat exchange pipe in high-pressure spiral tube heat exchanger[J].Cryogenic Technology,2011(1):23-28.
Authors:Zhang Qingsheng
Affiliation:Zhang Qingsheng(Kaifeng Dongjing Air Separation Group Co.,Ltd.,8# Beiguan Street,Kaifeng 475001,Henan,P.R.China)
Abstract:Gas leaks from the welds of expansion portion of the heat exchange pipe of Model DR87XX high-pressure spiral tube heat exchanger removed from one air separation plant,which is attributed to excessive high expanding pressure.After repair as per the detailed repair scheme,the high-pressure spiral tube heat exchanger is recovered to normal run.Here,the expansion + strength welding mode used for tube-plate and heat exchange pipe in DR87XX high-pressure spiral tube heat exchanger is briefed,the expansion test be...
Keywords:High-pressure spiral tube heat exchanger  Heat exchange pipe  Repair  Expansion  Strength welding  Expanding test  