Flow regimes and mass transfer in counter-current bubble columns
Authors:S Uchida  S Tsuyutani  T Seno
Abstract:Counter current bubble columns have the feature that specific gas-liquid interfacial area and gas holdup are larger than those for standard and cocurrent bubble columns. In this study, three different flow regimes, churn-turbulent flow, bubble flow and bubble down-flow, have been observed in a counter-current bubble column and correlations of gas holdup and volumetric liquid-phase mass transfer coefficient have been proposed as functions of operating variables such as the superficial velocities of gas and liquid, the gas-liquid slip velocity and the liquid properties.
Keywords:bubble column  counter-current  gas holdup  bubble column  mass transfer  gas-liquid