摘    要:铬(Ⅳ)对血红蛋白模拟酶催化荧光体系具有强烈的猝灭作用, 据此建立了一种酶催化分光荧光法测定铬(Ⅳ)的新方法。研究了溶液酸度、L-酪氨酸浓度、血红蛋白浓度、H2O2浓度及反应时间等因素对体系的影响。在pH10.4的NH3·H2O-NH4Cl缓冲溶液中, 当L-酪氨酸、血红蛋白和H2O2的浓度分别为1.4×10-4mol/L、1.0×10-6mol/L和3.5×10-5mol/L时, 测定铬(Ⅳ)的线性范围为2.0×10-6~1.0×10-4mol/L, 检出限为1.1×10-8mol/L。1000倍NO3-、SO42-、Na+、K+、Cl-、Br-, 300倍PO43-、Al3+、NH4+, 50倍Mn2+、Mg2+、Fe2+、Cu2+, 1倍Fe3+对铬(Ⅳ)的测定没有干扰。干扰较大的Fe3+, 可加入过量的柠檬酸掩蔽。对浓度为4.8×10-5mol/L的铬(Ⅳ)进行11次平行测定, 其相对标准偏差为2.8%。该法已成功地应用于环境水样中铬(Ⅳ)含量的测定。

关 键 词:铬    催化  分光荧光法  血红蛋白  环境水样  
收稿时间:2013-05-31

Determination of trace chromium in environmental water by enzymatic catalytic spectrofluorimetry
TIAN Feng-shou,CHEN Ya-hong,FANG Lei.Determination of trace chromium in environmental water by enzymatic catalytic spectrofluorimetry[J].Metallurgical Analysis,2013,33(5):55-58.
Authors:TIAN Feng-shou  CHEN Ya-hong  FANG Lei
Affiliation:Department of Chemistry, Zhoukou Normal University, Zhoukou 466001,China
Abstract:According to strong quenching effect of chromium on the catalytic fluorescence system of hemoglobin analog enzyme, a novel enzymatic catalytic spectrofluorimetry for determining chromium was established. The influence of acidity, L-tyrosine concentration, hemoglobin concentration, H2O2 concentration and reaction time on the system was studied. In NH3·H2O-NH4Cl buffer solution of pH 10.4 and the presence of 1.4×10-4 mol/L L-tyrosine, 1.0×10-6 mol/L hemoglobin and 3.5×10-5 H2O2, the linear range for the determination of chromium was 2.0×10-6-1.0×10-4 mol/L and the detection limit was 1.1×10-8 mol/L. 1000 times of NO3-, SO42-, Na+, K+, Cl- and Br-, 300 times of PO43-, Al3+, NH4+ and 50 times of Mn2+, Mg2+, Fe2+, Cu2+ and 1 time of Fe3+ did not interfere in the determination of chromium. Fe3+ which had more interference could be masked by adding an over dose of citric acid. The RSD was 2.8% for 11 parallel determination of 4.8×10-5 mol/L chromium,. The method was successfully applied for determining chromium in the environment water.