摘    要:阐述了炼油厂循环水系统漏油时的查漏方法及处理过程。根据季铵盐“12 2 7”在循环水 (含油 )处理过程中所起的杀菌剥离、增容和絮凝作用 ,提出用“12 2 7”清洗被油品污染的循环水系统。此方法同时也为采用“水中含油对比法”查找水冷设备泄漏点提供了条件。

关 键 词:循环水  油品  污染  季铵盐  清洗剂
文章编号:1007-015X(2004)05-0042-02
修稿时间:2004年4月18日

Leak Detection of Water Coolers in Refinery and Cleaning of Circulating Water System
Huang Kegen Anqing Petrochemical Company/SINOPEC.Leak Detection of Water Coolers in Refinery and Cleaning of Circulating Water System[J].Petrochemical Corrosion and Protection,2004,21(5):42-43,47.
Authors:Huang Kegen Anqing Petrochemical Company/SINOPEC
Abstract:The leak detection techniques and leak handling process of the refinery circulating water system are described. The quaternary ammonium salt 1227 is recommended for cleaning the circulating water system contaminated by oil based upon its performances in bacteria killing, spalling, thickening and flocculation in cooling water (containing oil) treatment.
Keywords:circulating water  oil  contamination  quaternary ammonium salt  cleaning agent