首页 | 官方网站   微博 | 高级检索  
     


Coupling of standard condensing nuclear power stations to horizontal aluminum tubes multieffect distillation plants
Authors:Joseph
Affiliation:

ADAR (Israel Atomic Energy Commission) Israel

Abstract:No large nuclear back-pressure turbines are available to day. Standard condensing nuclear turbines could operate continuously with a back-pressure of up to 7″ Hg, exhausting huge amounts of steam at 56°C - 640°c with a loss of electricity production of only 6%–10%. p]The horizontal aluminium tube multieffect distillation process developed by “Israel Desalination Engineering Ltd.” is very suitable for the use of such low-grade heat. A special flash-chamber loop constitutes a positive barrier against any possible contamination being carried over by the steam exhausted from the turbine to the desalination plant. The operation is designed to be flexible so that the power plant can be operated either in conjunction with the desalination plant, or as a single purpose plant. Flow sheets, heat and mass balances have been prepared for eight different combinations of plants. Only standard equipment is being used in the power plant.

The desalination plant consists of 6 to 12 parallel double lines, each of them similar to a large prototype now being designed.

Water production varies between 50 and 123 MGD and water cost between 90 and 137 ¢/1000 gallons.

Costs are based on actual bids.

Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23