Affiliation:1. Department of Basic Sciences, Deanship of Preparatory Year and Supporting Studies, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 34212, Saudi Arabia;2. Sudan University of Science and Technology College of Medical Radiologic Science, P.O. Box 1908, Khartoum, Sudan;3. Prince Sattam Bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, PO Box 422, Alkharj 11942, Saudi Arabia;4. Department of Biology, Turabah University College, Taif University, P.O.Box 11099, Taif 21944, Saudi Arabia;5. Nuclear Engineering Department, Faculty of Engineering, King Abdulaziz University, P.O. Box 80204 Jeddah 21589 Saudi Arabia
Abstract:This study aims to estimate the effective radiation dose and organ dose from head CT procedures. It was conducted in three main private hospitals in Khartoum State-Sudan, using Toshiba machines with 64 slices. The total number of patients included in this study was 142 patients (82 males and 60 females). The effective dose and organ dose were calculated by CT Expo software. The effective dose slightly varied among patients according to gender and age. The effective dose for female patients (5.99 mSv) was higher than that for male patients (5.84 mSv), and the pediatric dose (5.46 mSv) was lower than the adults’ dose (5.94 mSv).The dose for eye lens was found lower for male patients (89.117 mSv) than the dose for female patients (94.62) mSv). According to patients’ age: the dose received by the lens of the eye was much lower in pediatric (79.93 mSv) than the adults (92.41 mSv). The dose for thyroid in female patients (33.52 mSv) was higher than the male patients (28 mSv). The pediatric dose (28.34 mSv) was lower than the adults’ dose (30.64 mSv).Departmental imaging protocol and lack of training among hospital staff are expected to be responsible for these variations. Therefore, this study recommends that the CT technologists be trained on suitable strategies to achieve dose optimization. Moreover, patients’ doses must be monitored regularly.
Keywords:MDCT  Effective dose  Organ dose  Eye lens  Thyroid gland  Radiation risk
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号