首页 | 官方网站   微博 | 高级检索  
     


Arterial oxygen desaturation during non-sedated diagnostic upper gastrointestinal endoscopy
Authors:T Iwao  A Toyonaga  H Harada  K Harada  S Ban  M Ikegami  K Tanikawa
Affiliation:Department of Medicine II, Kurume University School of Medicine, Japan.
Abstract:We studied oxygen saturation (SaO2) using a pulse oximeter in 120 patients undergoing non-sedated diagnostic upper gastrointestinal endoscopy. The baseline SaO2 was 98.3 +/- 1.0%. During the procedure, absence of oxygen desaturation (SaO2 > or = 95%) was found in 56%, mild oxygen desaturation (95% > SaO2 > or = 90%) in 35%, and severe oxygen desaturation (SaO2 < 90%) in 9%. Age (p = 0.56), gender (p = 0.47), smoking (p = 0.35), hemoglobin level (p = 0.52), body mass index (p = 0.27), or total endoscopy time (p = 0.72) was not related to the degree of oxygen desaturation. These results suggest that oxygen desaturation is frequently observed during non-sedated diagnostic upper gastrointestinal endoscopy although severe oxygen desaturation, which may induce rare but serious cardiopulmonary events, is not common. Furthermore, we cannot predict in which patients desaturation will occur. We therefore recommend continuous monitoring of arterial oxygenation in all patients during the procedure.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23