摘    要:为进一步优化核电站二回路水化学工况,降低二回路水化学运行成本,分析了核电站二回路采用单一碱化剂存在的问题,提出了乙醇胺和氨复合应用的对策和基本依据。采用Chemworks软件,计算乙醇胺和氨不同配比复合应用于典型核电站二回路系统时不同部位工质的碱化剂浓度及pH值,筛选出了最佳乙醇胺质量分数(wETA)和氨质量分数(wNH3)配比及其范围,并通过高压釜试验验证了理论计算结果。研究表明:当核电站二回路给水中wETAwNH3≈4∶1、2×10-6wETA≤4×10-6、0.5×10-6wNH3≤1×10-6时,应用效果较好。

关 键 词:核电站  二回路  水化学工况  乙醇胺    碱化剂复合应用  碱化剂配比  
收稿时间:2018-10-16
修稿时间:2018-12-27

Feasibility Study on Combined Application of Ethanolamine and Ammonia in the Secondary Circuit of Nuclear Power Plant
ZHAO Yongfu,JIANG E,GONG Bin,WEN Juhua,TANG Min,YIN Zhaohui,HE Yanchun.Feasibility Study on Combined Application of Ethanolamine and Ammonia in the Secondary Circuit of Nuclear Power Plant[J].Electric Power,2019,52(4):127-132.
Authors:ZHAO Yongfu  JIANG E  GONG Bin  WEN Juhua  TANG Min  YIN Zhaohui  HE Yanchun
Affiliation:Nuclear Power Institute of China, Chengdu 610213, China
Abstract:The problems from the usage of single alkalinity treatment were analyzed and then the countermeasures and basic standards of combined application of ethanolamine (ETA) and ammonia in the secondary circuit of nuclear power plant (NPP) were put forward in order to further optimize water chemistry condition and reduce chemical operation cost. With various combination ratios of ethanolamine and ammonia, the alkalinity concentration and pH values at different parts of secondary circuit of a typical nuclear power plant were calculated by CHEMWORKS. The optimum concentration ratio and range of ethanolamine and ammonia were filtered and verified by theoretical calculation and autoclave tests. The results show that satisfactory outcome can be attained in practice when the concentrations of ethanolamine and ammonia in the feed-water of secondary circuit meet the following requirements: wETA:wNH3≈4:1, 2×10-6wETA≤4×10-6, 0.5×10-6wNH3≤1×10-6.
Keywords:nuclear power plant  secondary circuit  water chemistry condition  ETA  ammonia  combined application of alkalinity  concentration ratio of alkalinity  