Simulation and measurement of the resonant Schottky pickup
Affiliation:ZANG Yong-Dong 1,2,1 WU Jun-Xia 1 ZHAO Tie-Cheng 1 ZHANG Sheng-Hu 1 MAO Rui-Shi 1 XU Hu-Shan 1 SUN Zhi-Yu 1 MA Xin-Wen 1 TU Xiao-Lin 1,2 XIAO Guo-Qing 1 F. Nolden3 P. Hülsmann3 Yu. A. Litvinov3 C. Peschke3 P. Petri3 M. S. Sanjari3 M. Steck3 1 Institute of Modern Physics,Chinese Academy of Sciences,Lanzhou 730000,China 2 Graduate University of Chinese Academy of Sciences,Beijing 100049,China 3 Gesellschaft fu¨r Schwerionenforschung,Darmstadt,Germany
Abstract:A resonant Schottky pickup with high sensitivity, built by GSI, will be used for nuclear mass and lifetime measurement at CSRe. The basic concepts of Schottky noise signals, a brief introduction of the geometry of the detector, the transient response of the detector, and MAFIA simulated and perturbation measured results of characteristics are presented in this paper. The resonant frequency of the pickup is about 243 MHz and can be slightly changed at a range of 3 MHz. The unloaded quality factor is about 10...
Keywords:resonant Schottky pickup  Schottky signal  characteristics of the eigenmode TM010  