BSA法测定超滤膜截留率的不确定度评定
引用本文:王旭亮,赵静红,李宗雨,郝军,潘献辉.BSA法测定超滤膜截留率的不确定度评定[J].计量学报,2019,40(2):337-342.
作者姓名:王旭亮  赵静红  李宗雨  郝军  潘献辉
作者单位:国家海洋局天津海水淡化与综合利用研究所,天津,300192;国家海水及苦咸水利用产品质量监督检验中心,天津,300192
基金项目:国家科技支撑计划项目(2014BAB06B00);中央级公益性科研院所基本科研业务费专项资金(K-JBYWF-2015-T15,K-JBYWF-2016-G15);国家海洋局青年海洋科学基金(2013450)
摘    要:截留性能是超滤膜重要的性能指标,截留率和切割分子量又是表征超滤膜截留性能的主要技术参数。基于GB/T 32360-2015《超滤膜测试方法》,依据JJF 1059-2012《测量不确定度评定与表示》,以牛血清白蛋白(BSA-67000)为标准物质,建立截留率测试结果的不确定度评定数学模型,全面分析不确定度来源,评定超滤膜截留率测试结果的不确定度。结果表明:BSA-67000的多分散系数(Mw /(Mn)为1.101,GPC谱图呈现单峰形式,结构明确、分子量分布窄,完全满足测试需要。对该结果进行了不确定度评定,当包含因子k=2,置信水平为95%时,扩展不确定度为7.86%,测试结果的不确定度主要来源于测试液取样、重复性测试和BSA-67000的紫外分光光度法测定。

关 键 词:计量学  超滤膜  截留率  牛血清白蛋白  测试  不确定度评定
收稿时间:2017-09-11

Uncertainty Evaluation for the Determination of the Retention Ratio of the Ultrafiltration Membrane by BSA-67000
WANG Xu-liang,ZHAO Jing-hong,LI Zong-yu,HAO Jun,PAN Xian-hui.Uncertainty Evaluation for the Determination of the Retention Ratio of the Ultrafiltration Membrane by BSA-67000[J].Acta Metrologica Sinica,2019,40(2):337-342.
Authors:WANG Xu-liang  ZHAO Jing-hong  LI Zong-yu  HAO Jun  PAN Xian-hui
Affiliation:1. The Institute of Seawater Desalination and Multipurpose Utilization, SOA (Tianjin), Tianjin 300192, China
2. National Quality Supervision and Inspection Center for Seawater & Brackish Water Utilization Products, Tianjin 300192, China
Abstract:Retention performance is the most important performance indicator of ultrafiltration membrane performance, including two technical parameters which are molecular weight cut off and retention.Based on GB/T 32360-2015 "Test Methods for Ultrafiltration Membrane", according to the JJF 1059-2012 "Evaluation and Expression of Uncertainty in Measurement", BSA-67000 was choosed as standard substance, evaluation mathematical model of uncertainty of retention test results was established to analyze the sources of uncertainty, and the retention test results were evaluated.The results indicated that the polydispersity coefficient(Mw /(Mn) of BSA-67000 is 1.101 and GPC spectrum showed a single peak form, in line with PEG clear structure, molecular weight distribution narrow features, which fully meet the testing needs.The results were evaluated uncertainty.It showed that expanded uncertainty is 7.86%, when coverage factor is k=2 and level of confidence is 95%.Uncertainty of the measurement results were mainly from the removing the test sample, repeatability and spectrophotometric determination of BSA-67000.
Keywords:metrology  ultrafiltration membrane  retention ratio  BSA-67000  determination  uncertainty evaluation  