首页 | 官方网站   微博 | 高级检索  
     


Effects of Ozonation on AOC Content of Humic Finnish Groundwater
Authors:Jarmo Sallanko  Tero Väisänen
Affiliation:1. Water Resources and Environmental Engineering Laboratory , University of Oulu , Oulu , 90014 , Finland;2. Environmental Testing and Monitoring Laboratory , Finnish Environment Institute , Oulu , 90570 , Finland
Abstract:The effects of ozonation on assimilable organic carbon (AOC) content of humic groundwater were investigated in batch experiments on three different groundwaters used as drinking water in Finland. All water samples had quite high concentrations of iron (range 2–10 mg/L) and manganese (range 0.1–0.2 mg/L) and therefore combined ozonation and filtration is a possible water purification method. The ozone dosage used varied from 0 to 16.6 mgO3/L (ΔO3/TOC?=?0–1.6). The ozone treatment increased the AOC concentration in the groundwater samples to different degrees. For example, an ozone dose of 3.9 mg/L increased the AOC concentration in different water as follows: from 49 μg/L to 55/L, from 7 μg/L to 119 μg/L and from 23 μg/L to 226 μg/L.
Keywords:Ozone  AOC  Bioactivity  Water Treatment  Groundwater Treatment  Oxidation  Biodegradability
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23