首页 | 官方网站   微博 | 高级检索  
     

环境温度对地震数据采集器时间精度的影响测试
引用本文:叶世山,谢剑波,陈洁,赵圣麟,吕金水,冯俊鹏,陈建涛,关作金,罗新恒,卢子晋,邓金,廖一帆,劳谦,丁莉莎.环境温度对地震数据采集器时间精度的影响测试[J].大地测量与地球动力学,2022,42(4):431-435.
作者姓名:叶世山  谢剑波  陈洁  赵圣麟  吕金水  冯俊鹏  陈建涛  关作金  罗新恒  卢子晋  邓金  廖一帆  劳谦  丁莉莎
作者单位:广东省地震局,广州市先烈中路 81 号,510070,珠海市泰德企业有限公司,广东省珠海市创新四路 60 号,519002
摘    要:为适应地震数据采集器时间精度测试的需要,采用特定电路将普通参考时钟源输出的分脉冲信号扩展至占空比为50%,再利用扩展后的分脉冲信号在室温、低温恒温及高温恒温环境中对地震数据采集器时间精度进行测试,研究环境温度对地震数据采集器时间精度的影响。结果表明,地震数据采集器时间精度及漂移趋势受环境温度变化影响,0.5 h内发生约1 ℃的温度变化可引起地震数据采集器产生μs级时钟精度变化和守时趋势变化,通过温度对时间数值积分反映的温度变化累积效应与地震数据采集器时钟漂移的趋势变化具有较好的对应关系;恒温环境下地震数据采集器的时标延迟变化表现出单调特性,变化率由个体使用的晶振器件决定,并与环境温度有关。

关 键 词:地震数据采集器  时间精度  环境温度影响  

Testing of Ambient Temperature Influence on Time Tag Accuracy of Seismic Digitizer
YE Shishan,XIE Jianbo,CHEN Jie,ZHAO Shenglin,Lü Jinshui,FENG Junpeng,CHEN Jiantao,GUAN Zuojin,LUO Xinheng,LU Zijin,DENG Jin,LIAO Yifan,LAO Qian,DING Lisha.Testing of Ambient Temperature Influence on Time Tag Accuracy of Seismic Digitizer[J].Journal of Geodesy and Geodynamics,2022,42(4):431-435.
Authors:YE Shishan  XIE Jianbo  CHEN Jie  ZHAO Shenglin  Lü Jinshui  FENG Junpeng  CHEN Jiantao  GUAN Zuojin  LUO Xinheng  LU Zijin  DENG Jin  LIAO Yifan  LAO Qian  DING Lisha
Abstract:To meet the needs of time accuracy testing of seismic digitizer, we use a specific circuit to extend the PPM(pulse per minute) output by the common reference clock source to a duty cycle of 50%. With the extended PPM, the time tag accuracy of seismic digitizer is tested at room temperature, constant low temperature and constant high temperature environments. We study the influence of ambient temperature on time tag accuracy. The results show that time tag accuracy and drift trend of seismic digitizer are affected by the change of ambient temperature. A temperature change of about 1 ℃ in half an hour can cause the time tag accuracy change of microsecond stage and the drift trend change of time tag delay. The cumulative effect of temperature change reflected by temperature to time numerical integration has good correspondence with the drift trend change of seismic digitizer. The time tag delay at constant temperature environment shows monotonous characteristics. The drift rate is determined by the crystal resonators used by individual digitizer, and it is associated with the ambient temperature.
Keywords:seismic digitizer  time tag accuracy  influence of ambient temperature  
本文献已被 万方数据 等数据库收录!
点击此处可从《大地测量与地球动力学》浏览原始摘要信息
点击此处可从《大地测量与地球动力学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号