首页 | 官方网站   微博 | 高级检索  
     

重整装置预加氢进料/产物换热器内漏分析与判断
引用本文:竺家培,高秋云.重整装置预加氢进料/产物换热器内漏分析与判断[J].炼油技术与工程,2011,41(3):34-37.
作者姓名:竺家培  高秋云
作者单位:中国石化青岛炼化,山东省青岛市,266500
摘    要:介绍了一种通过比较预加氢反应器进料与生成油换热器、汽提塔进料与塔底油换热器、汽提塔进料与分馏塔塔底油换热器以及预加氢进料与分馏塔顶油换热器油样中总硫含量的变化来分析与判断预加氢进料换热器内漏的方法.正常生产情况下,预加氢精制油中总硫的含量应该是比较低的.如果精制油中总硫质量分数超过0.5%,则或是催化剂活性下降,或是相...

关 键 词:催化重整  预加氢  换热器  内漏  分析  判断

Analysis and diagnosis for leaks in pre-hydrotreating feed/effluent heat exchanger of catalytic reformer
Zhu Jiapei,Gao Qiuyun.Analysis and diagnosis for leaks in pre-hydrotreating feed/effluent heat exchanger of catalytic reformer[J].Petroleum Refinery Engineering,2011,41(3):34-37.
Authors:Zhu Jiapei  Gao Qiuyun
Affiliation:Zhu Jiapei,Gao Qiuyun(SINOPEC Qingdao Refining & Chemical Co.,Ltd.,Qingdao Shandong 266500)
Abstract:A method is presented for the analysis and diagnosis of the pre-hydrotreating feed/product heat exchanger leak through the analysis of the changes of sulfur content in pre-hydrotreating feed/product heat exchanger,stripping tower feed/bottom oil heat exchanger,stripping tower feed/ bottom oil of fractionating tower heat exchanger,pre-hydrotreating feed/overhead oil of fractionating tower heat exchanger.In normal operating conditions,the total sulfur in pre-hydrotreated oil is lower.If sulfur in pre-hydrotre...
Keywords:catalytic reformer  pre-hydrotreating  heat exchanger  internal leak  analysis  diagnosis  