Abstract: | This paper describes a simple method for incorporating the effects of the uniform risk spectra (URS) in the seismic probabilistic safety assessment (PSA) for a pressurized water reactor (PWR) power station. The “traditional” fragility parameters for a range of critical equipment items in a PWR power station on two typical UK sites are modified to incorporate the URS using this simple method and the effect on the high confidence low probability of failure (HCLPF) acceleration levels and seismic-induced failure probabilities of the equipment items is examined. The results illustrate the potential benefit of using the URS in the seismic PSA for a PWR power station. |