Performance of solar assisted heatpump systems in residential applications
Authors:S Kugle  S Green  A Haji-Sheikh  DYS Lou
Affiliation:Solar Energy Research Facilities, Department of Mechanical Engineering, University of Texas atArlington, Arlington, TX 76019, U.S.A.
Abstract:In this experimental study, several solar-assisted heating and cooling configurations have beenconsidered for a basic system comprised of a two-speed heat pump, photovoltaic (PV) arrays, solar thermal collectors, and thermal storage. The objective of the study was to determine the performance of the PV arrays at decreased insolation, the effects of air preheat by solar thermal energy on heat pump operation, and cooling system performance under two different configurations. During the entire operation, the PV arrays converted 4.7 per cent (9.5 MWh) of the incident solar insolation to d.c. power, of which 54.6 per cent was used by the residence. This contributed 23.4 per cent of the total house electrical demand. The remaining 45.4 per cent of the output was fed to the utility, indicating the arrays and the heat pump were not properly sized with each other. Based on results from the winter heating operation, it is shown that for the particular heating system consdered, the best performance is attained when the solar heating is used alone. By using the heat pump as a booster, the remaining available solar energy left in the storage tank can be used with good seasonal performance factor. Summer cooling operation consisted of two sequential cooling configurations. In the first cooling test, the heat pump was operated to either the house or storage when the PV array generation level was greater than the energy demand of the heat pump and associated equipment. When the array output level was less than the cooling system demand, the operating strategy was that of an off-peak cooling operation to chill the water storage. Utilization of chilled water storage was not realized in the first cooling test because of the inherent inefficient design of the Tri-X coil. The capacity at low-speed heat pump operation was too small to effect significant cooling of the water loop; whereas high-speed heat pump operation in attempting to chill water (fan operation absent) caused frosting of the coil. The heat pump was utilized only to maintain chilled water storage in the second cooling test, without heat transfer through the Tri-X coil. Cooling system performance obtained in cooling test 2 using the Ametex exchanger was considerably improved over the test 2 performance with the Tri-X coil.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号