摘    要:利用折叠腔法-珀干涉仪实现了高精度位移测量,使干涉级次的当量缩小了一倍,而且扩大了法-珀干涉仪的测量范围。但折叠腔法-珀干涉仪透射光的相位在经立体棱镜反射时发生了变化,本文对折叠腔法-珀干涉仪及其透射光相位的变化进行了分析研究。

关 键 词:干涉仪  折叠谐振腔  位移测量  相位

A Study of Folded Cavity Fabry-Perot Interferometer and Its Transmitting Light Phase Changes
Cao Feng,Xu Yi.A Study of Folded Cavity Fabry-Perot Interferometer and Its Transmitting Light Phase Changes[J].Opto-Electronic Engineering,1993,20(3):30-33.
Authors:Cao Feng  Xu Yi
Abstract:The equivalent of the interference order has been reduced by one time and themeasuring range of the Fabry-Perot interferometer has been enlarged when the high accu-racy displacement measurement has been carried out by using folded cavity Fabry-Perotinterferometer.The light phase transmitted by Fabry-Perot interferometer will be changedwhenit is reflected by the stereo-prism. The folded cavity Fabry-Perot interferometer andits transmitted light phase changes are analysed.
Keywords:Fabry-Perot interferometers  Folded resonators  Displacement measuremeut  Transmission light  Phase errors  