首页 | 官方网站   微博 | 高级检索  
     


Multi-frequency ECT with AMR sensor
Authors:DF He  M Shiwa  JP Jia  J Takatsubo  S Moriya
Affiliation:1. National Institute for Materials Science, Sengen 1-2-1, Tsukuba, 305-0047, Japan;2. National Key Laboratory for Surface Physics and Chemistry, China Academy of Engineering Physics, Sichun, China;3. Advanced Industrial Science and Technology 1-2-1 Namiki, Tsukuba, 305-8564, Japan;4. Japan Aerospace Exploration Agency, Sengen 2-1-1, Tsukuba, 305-8505, Japan
Abstract:Multi-frequency Eddy current testing (ECT) system with high sensitive AMR sensor was developed. By subtracting the signals of two frequencies, the influence of lift off variance could be reduced. As a testing, a specimen of copper plate with grooves and slits was used to simulate the combustion chamber of liquid rocket and the defects. Three defects, with the width of 0.2 mm, the length of 4 mm and the depth of 0.2, 0.5, and 0.8 mm were made in the bottom of the grooves. Multi-frequency ECT experiments were done and the defects with the depth of 0.8 and 0.5 mm could be successfully detected.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23