摘    要:变压器差动保护中传统的二次谐波制动方案在变压器空载合闸、内部故障或外部故障切除时,若TA饱和,变压器差流中二次谐波含量较低,差动保护容易误动。文章对变压器差流进行了谐波分析,针对传统二次谐波制动存在的一些问题,提出了基于二次谐波幅值和相位综合判据的二次谐波制动法。研究了励磁涌流中二次谐波与基波之间特殊的相位关系,通过与二次谐波含量构成自适应调整二次谐波制动系数的综合制动判据,并用EMTP进行大量仿真实验,验证了所提出方案正确性和可靠性。

关 键 词:励磁涌流  二次谐波  综合制动方案  相位关系
收稿时间:2013/11/8 0:00:00
修稿时间:2013/11/8 0:00:00

The analysis and improvement of secondary harmonic restraint in Transformer differential protection
ZHANG Shuang-zi,WANG Zheng,SUN Shi-yong and DENG Rui.The analysis and improvement of secondary harmonic restraint in Transformer differential protection[J].Electrical Measurement & Instrumentation,2014,51(23).
Authors:ZHANG Shuang-zi  WANG Zheng  SUN Shi-yong and DENG Rui
Affiliation:State Grid Henan Electric Power Corporation Maintenance Company,State Grid Henan Electric Power Corporation Maintenance Company,State Grid Ping Ding-shan Power Supply Company,State Grid Henan Electric Power Corporation Maintenance Company
Abstract:If the TA is saturated, the traditional second harmonic restraint program of Transformer differential protection in transformer load switching, internal or external fault removal cause the differential protection malfunction because the second harmonic content is low. The harmonic analysis is carried out for the differential current in the text. To some problems for the traditional second harmonic restraint, The new second harmonic restraint program is proposed based on the amplitude and phase of the second harmonic comprehensive criterion. The phase relationship between the fundamental and the second harmonic is researched in inrush current. The integrated brake criterion is constituted by the second harmonic restraint coefficient adaptively with the second harmonic content. The correctness and reliability of the proposed scheme is verified through a large number EMTP simulation.