全文获取类型
收费全文 | 147篇 |
免费 | 2篇 |
学科分类
工业技术 | 149篇 |
出版年
2024年 | 1篇 |
2021年 | 2篇 |
2020年 | 3篇 |
2019年 | 3篇 |
2018年 | 2篇 |
2017年 | 5篇 |
2016年 | 1篇 |
2015年 | 6篇 |
2014年 | 1篇 |
2013年 | 6篇 |
2011年 | 2篇 |
2010年 | 3篇 |
2009年 | 6篇 |
2008年 | 6篇 |
2007年 | 9篇 |
2006年 | 13篇 |
2005年 | 13篇 |
2004年 | 13篇 |
2003年 | 1篇 |
2002年 | 7篇 |
2001年 | 4篇 |
2000年 | 4篇 |
1999年 | 6篇 |
1998年 | 6篇 |
1997年 | 7篇 |
1996年 | 3篇 |
1995年 | 5篇 |
1994年 | 3篇 |
1993年 | 1篇 |
1987年 | 1篇 |
1985年 | 1篇 |
1982年 | 1篇 |
1978年 | 1篇 |
1977年 | 2篇 |
1976年 | 1篇 |
排序方式: 共有149条查询结果,搜索用时 156 毫秒
1.
Improved modulation techniques for PWM-VSI drives 总被引:2,自引:0,他引:2
Blaabjerg F. Pedersen J.K. Thoegersen P. 《Industrial Electronics, IEEE Transactions on》1997,44(1):87-95
PWM-VSI based AC motor drives have two main problems. The inverter is nonlinear which causes instability problems in some specific working points of the AC machine and it emits acoustic noise due to the switching frequency. Nonlinearities like dead-time in the inverter, load dependent DC-link voltage ripple and the voltage drop across the switches are modeled and compensated by improved modulation techniques in order to obtain an almost ideal inverter. Different feedback and feedforward techniques are proposed. The acoustic noise is reduced by using a random modulation strategy. Measurements show a significant improvement by using feedforward and feedback techniques for linearizing the inverter. An improvement in reduction of the acoustic noise emission is also achieved by using random modulation. It is concluded that a combination of a random modulation strategy and feedforward/feedback techniques gives an almost ideal AC motor drive system 相似文献
2.
Blaabjerg F. Casadei D. Klumpner C. Matteini M. 《Industrial Electronics, IEEE Transactions on》2002,49(2):289-296
In this paper, the input current performance of matrix converters is analyzed, especially with reference to the operating conditions determined by unbalanced supply voltages. The space-vector modulation (SVM) technique is utilized to calculate the duty cycles of the active voltage vectors that must be applied, in each switching cycle period, in order to satisfy the input and output requirements. A detailed theoretical analysis of the input current harmonic content under unbalanced input voltage conditions is presented for two different current modulation strategies. On the basis of numerical simulations as well as measurements on a laboratory prototype setup, the strategies' performance are compared and the validity of the theoretical investigation confirmed. It is concluded that, when the input voltages are unbalanced to a significant extent, a dynamic input current modulation strategy has to be preferred, since a lower harmonic line current distortion will appear 相似文献
3.
Photovoltaic (PV) and other sources of renewable energy are being used increasingly in grid-connected systems, for which stronger power quality requirements are being issued. Continuous grid monitoring should be considered so as to provide safe connections and disconnections from the grid. This letter gives an overview of the methods used for online grid measurement with PV inverters. Emphasis is placed on a method based on the injection of a noncharacteristic harmonic in the grid. Since this injection is regarded as a disturbance for the grid, different issues, i.e., the influence on total harmonic distortion (THD), the accuracy of line impedance measurement and the ENS (German abbreviation of Main Monitoring units with allocated Switching Devices) detection are studied. Laboratory results conducted on an existing PV inverter are presented to demonstrate the behavior of the PV inverter under different grid conditions. Some of the injection parameters are tuned in order to get an accurate measurement of line impedance. 相似文献
4.
S. Multsch A. S. Alquwaizany O. A. Alharbi M. Pahlow H.-G. Frede L. Breuer 《国际水资源开发杂志》2017,33(2):292-309
Agriculture policy changes in Saudi Arabia are investigated by water footprint (WF) assessment. WF is calculated with the model SPARE:WATER for 3758 irrigated sites. The WF of agriculture areas (WFarea, km3 yr?1) has decreased (–17%) since the year 2000 to 13.84 km3 yr?1 (2011), which is mainly caused by the reduction of cropland by –33%. Nevertheless, water consumption per field has increased about 16%, which can be attributed to the cultivation of fodder crops (+12%). A scenario analysis revealed that a shifting cropping pattern towards less fodder crops reduces WFarea by –15%, and implementing improved irrigation technology leads to a combined reduction of up to 32% 相似文献
5.
MR Ujhelyi AP Winecoff M Schur T Frede MB Bottorff M Gabel ML Markel 《Canadian Metallurgical Quarterly》1996,110(3):784-790
BACKGROUND: Transplantation of lung allografts from the same donor into 2 recipients ("twinning") provides an opportunity to study recipient and donor factors that influence early allograft function. METHODS: Twenty-seven pairs of recipients were identified and evaluated using multivariate logistic regression analysis (p < 0.05). Four measures of early graft function were analyzed: alveolar-arterial gradient in the operating room, first alveolar-arterial gradient in the intensive care unit, alveolar-arterial gradient at 24 hours, and days of mechanical ventilation. RESULTS: Analysis of the pooled data without regard to pairing showed that alveolar-arterial gradient in the operating room was influenced by donor age, length of donor hospitalization, recipient mean pulmonary artery (PA) pressure at unclamping, and transplantation of a left lung. The alveolar-arterial gradient in the intensive care unit was correlated with donor age, donor cause of death, and mean PA pressure on arrival in that unit. Only mean PA pressure remained significant at 24 hours. Days of mechanical ventilation was determined by mean PA pressure on arrival in the intensive care unit, drop in mean PA pressure during operation, and diagnosis of the recipient. In the paired analysis, receiving a left lung, recipient diagnosis (pulmonary hypertension worse than others), and need of cardiopulmonary bypass were significantly associated with immediate graft dysfunction, although these influences did not persist beyond the immediate postoperative period. Donor arterial oxygen tension and time of ischemia were not significant predictors in any analysis. CONCLUSIONS: Immediate allograft function was associated with donor-related characteristics initially, but these lost importance over the ensuing 24 hours. Recipient PA pressure was an immediate and persisting influence. In the analysis of differences in function between the members of each pair, transplantation of the left lung, recipient diagnosis, and cardiopulmonary bypass were identified, but their influence did not persist beyond the first 6 hours. 相似文献
6.
Marcelo Godoy Simões Tiago Davi Curi Busarello Abdullah Saad Bubshait Farnaz Harirchi José Antenor Pomilio Frede Blaabjerg 《International journal of control》2016,89(4):850-870
This paper presents interactive smart battery-based storage (BBS) for wind generator (WG) and photovoltaic (PV) systems. The BBS is composed of an asymmetric cascaded H-bridge multilevel inverter (ACMI) with staircase modulation. The structure is parallel to the WG and PV systems, allowing the ACMI to have a reduction in power losses compared to the usual solution for storage connected at the DC-link of the converter for WG or PV systems. Moreover, the BBS is embedded with a decision algorithm running real-time energy costs, plus a battery state-of-charge manager and power quality capabilities, making the described system in this paper very interactive, smart and multifunctional. The paper describes how BBS interacts with the WG and PV and how its performance is improved. Experimental results are presented showing the efficacy of this BBS for renewable energy applications. 相似文献
7.
Fuses may in the future enter into the DC link of voltage-source converters and the harmonic power losses prediction in fuses is very important for the manufacturers in order to predict lifetime and protection level of the converter. The DC-link current has a high harmonic content for an inverter that uses any kind of space-vector modulation strategy. The aim of this paper is to find a useful approximation for the AC resistance of a fuse and to predict the harmonic power losses in it when it is fed from an inverter. 相似文献
8.
Hanigovszki N. Poulsen J. Blaabjerg F. 《Industry Applications, IEEE Transactions on》2004,40(3):845-852
When an induction machine is supplied with a voltage-source pulsewidth-modulation (PWM) inverter, a ringing voltage overshoot appears at motor terminals due to steep PWM voltage pulse propagation along the motor cable. It has been reported that in particular situations, when very long motor cables are used and retrofit installations, the overvoltage could stress motors with poor insulation. This paper presents a novel inverter output filter topology consisting of an LC filter which has the star point of the common-mode capacitors clamped to the + and - dc-link rails by the means of two diodes. The proposed filter drastically reduces the voltage overshoot at the motor terminals, thus reducing motor insulation stress. This is a cheap alternative to more known industrial solutions. 相似文献
9.
Compensation of cable voltage drops and automatic identification of cable parameters in 400 Hz ground power units 总被引:1,自引:0,他引:1
Borup U. Nielsen B.V. Blaabjerg F. 《Industry Applications, IEEE Transactions on》2004,40(5):1281-1286
In this paper a new cable voltage drop compensation scheme for ground power units (GPU) is presented. The scheme is able to predict and compensate the voltage drop in an output cable by measuring the current quantities at the source. The prediction is based on an advanced cable model that includes self and mutual impedance parameters. The model predicts the voltage drop at both symmetrical and unbalanced loads. In order to determine the cable model parameters an automatic identification concept is derived. The concept is tested in full scale on a 90-kVA 400-Hz GPU with two different cables. It is concluded that the performance is significantly improved both with symmetrical and unsymmetrical cables and with balanced and unbalanced loads. 相似文献
10.
A Statistical Model for Interpretation of the Crystallization of Fatty Acid Mixtures A molecular-statistical model is developed to explain the mixed crystal forms and the melting behaviour of binary fatty acid mixtures exemplified by the system stearic acid/palmitic acid. In this model, we proceed from the existence of three types of double molecules (SS-, SP- and PP-molecules), the frequency of which only depends on the mixture ratio (hypergeometric distribution). Proceeding from this model, a subdivision of the concentration range into three sections may be made in accordance with the measuring results. In each of these three sections, a more or less defective crystal lattice may prevail which is built up mainly of SS-, SP- or PP-double molecules and contains centres of disturbance the portion of which is depending upon the mixture ratio. Due to the dependence of the density of disturbance centres on the concentration it is possible to make a qualitative prediction of the melting behaviour of the binary fatty acid mixtures. 相似文献