排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.
This work introduces the branching ratio(BR) method for determining relative spectral responses,which are needed routinely in laser induced breakdown spectroscopy(LIBS). Neutral and singly ionized Ti lines in the 250–498 nm spectral range are investigated by measuring laser-induced micro plasma near a Ti plate and used to calculate the relative spectral response of an entire LIBS detection system. The results are compared with those of the conventional relative spectral response calibration method using a tungsten halogen lamp, and certain lines available for the BR method are selected. The study supports the common manner of using BRs to calibrate the detection system in LIBS setups. 相似文献
2.
3.
4.
Spectroscopy in the soft X-ray and extreme ultraviolet(XEUV) region is very important in magnetic fusion research.Recently,two flat-field spectrometers that utilize a varied line spacing grating to image the spectra of 1-13 nm and 5-50 nm were installed on EAST for core impurity emission monitoring and impurity transport study.The instruments were proven to be capable of observing spectral lines from low-Z impurities(Li,C,O,N,Ar,etc.) and highly ionized medium- and high-Z impurities(Fe,Cr,Ni,Cu,Mo,etc.).For example,spectra in the wavelength intervals of 1-2 nm and 5-13 nm contained strong metal lines,especially molybdenum lines during H-mode phases.Argon and nitrogen lines were also observed,which were injected for diagnostic purposes.Impurity lines were identified and compared to measurements on other magnetic fusion research devices.Detailed measurements of radial emission profiles from various impurity line emissions were also presented. 相似文献
5.
Laser-induced breakdown spectroscopy has become a general-purpose technique, and internal standard calibration is a common method for quantitative analysis. Calibration models should be reconstructed for different systems and application environments. This study presents an efficient procedure in the construction and selection of calibration models for LIBS analysis. The procedure concludes data preprocess, calibration model construction, and concentration calculation. These steps can be programmed without manual intervention. Results of the quantitative analysis of Ni-based alloys using the proposed procedure are presented in this study.Ten elements are calibrated, and most have an average relative standard error of less than 10%.The proposed procedure is an effective process for constructing and selecting calibration models. 相似文献
6.
1