首页 | 官方网站   微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   15篇
  免费   0篇
环境安全   15篇
  2013年   7篇
  2007年   1篇
  2006年   2篇
  2005年   1篇
  2002年   2篇
  2001年   1篇
  1992年   1篇
排序方式: 共有15条查询结果,搜索用时 17 毫秒
1.
Diffusive sampling of a mixture of 42 volatile organic compounds (VOCs) in humidified, purified air onto the solid adsorbent Carbopack X was evaluated under controlled laboratory conditions. The evaluation included variations in sample air temperature, relative humidity and ozone concentration. Linearity of samples with loading was examined both for a constant concentration with time varied up to 24 h and for different concentrations over 24 h. Reverse diffusion and its increase with accumulation of sample were determined for all compounds. Tubes were examined for blank levels, change of blanks with storage time, and variability of blanks. Method detection limits were determined based on seven replicate samples. Based on this evaluation, 27 VOCs were selected for quantitative monitoring in the concentration range from approximately 0.1 to 4 ppbv. Comparison results of active and diffusive samples taken over 24 h and under the same simulated ambient conditions at a constant 2 ppbv were interpreted to estimate the effective diffusive sampling rates (ml min(-1)) and their uncertainties and to calculate the corresponding diffusive uptake rates (ng ppmv(-1) min(-1)).  相似文献   
2.
ABSTRACT

Dalton's law of partial pressures and the hypothesis that water vapor equilibrium in a canister is identical to that established above liquid water are used to predict the variation of the percent relative humidity (%RH) of air released from canisters used in ambient air sampling, typically 6-L canisters pressurized with 18 L of air. When (and if) the water vapor partial pressure in a canister exceeds its saturation vapor pressure, water vapor condensation begins and the condensation rate equals the sampling rate of water vapor into the canister. Under constant temperature conditions, the air subsequently released from the canister is less humid than the original sample, following the relationship %RH = 100% (6 L/Vs) for Vs> Vr, where Vs is the residual air volume (referenced to atmospheric pressure), and Vr is shown to depend on the %RH of the ambient air sample. Vr is the residual air volume at which water is completely removed (except for adsorbed water vapor) from the canister wall. For Vs < Vr, the predicted %RH is constant and equal to its value at Vr. Experimental values agree reasonably well with predictions at both high (90%) and low (34%) RH. However, experimental values are often slightly displaced (usually towards lower values of %RH) for mid-range %RH (61%) and variations in %RH near Vr change from canister to canister.  相似文献   
3.
Analytical results obtained by thermal desorption GC/MS for 24 h diffusive sampling of 11 volatile organic compounds (VOCs) are compared with results of time-averaged active sampling at a known constant flow rate. Air samples were collected with co-located duplicate diffusive sampling tubes and one passivated canister. A total of eight multiple-component sampling events took place at fixed positions inside and outside three private homes. Subsequently, a known amount of sample air was transferred from the canister to an adsorbent tube for analysis by thermal desorption GC/MS. Results for the 11 most prevalent compounds--Freon 11, 1,3-butadiene, benzene, toluene, tetrachloroethene, ethylbenzene, m,p-xylene, o-xylene, 4-ethyltoluene, 1,3,5-trimethylbenzene, and p-dichlorobenzene--show that the ratio of average study values (diffusive sampling to active sampling) is 0.92 with 0.70 and 1.14 extreme ratios. Absolute percent difference for duplicate samples using diffusive sampling was <10% for the four most prevalent compounds. Agreement between the two sampling approaches indicates that the prediction of approximately constant diffusive sampling rates based on previous laboratory studies is valid under the field conditions.  相似文献   
4.
Optical remote measurement of toxic gases.   总被引:5,自引:0,他引:5  
Enactment of the Clean Air Act Amendments (CAAA) of 1990 has resulted in increased ambient air monitoring needs for industry, some of which may be met efficiently using open-path optical remote sensing techniques. These techniques include Fourier transform spectroscopy, differential optical absorption spectroscopy, laser long-path absorption, differential absorption lidar, and gas cell correlation spectroscopy. With this regulatory impetus, it is an opportune time to consider applying these technologies to the remote and/or path-averaged measurement and monitoring of toxic gases covered by the CAAA. This article reviews the optical remote sensing technology and literature for that application.  相似文献   
5.
The capping of stationary source emissions of NOx in 22 states and the District of Columbia is federally mandated by the NOx SIP Call legislation with the intended purpose of reducing downwind O3 concentrations. Monitors for NO, NO2, and the reactive oxides of nitrogen into which these two compounds are converted will record data to evaluate air quality model (AQM) predictions. Guidelines for testing these models indicate the need for semicontinuous measurements as close to real time as possible but no less frequently than once per hour. The measurement uncertainty required for AQM testing must be less than +/-20% (+/-10% for NO2) at mixing ratios of 1 ppbv and higher for NO, individual NOz component compounds, and NOy. This article is a review and discussion of different monitoring methods, some currently used in research and others used for routine monitoring. The performance of these methods is compared with the monitoring guidelines. Recommendations for advancing speciated and total NOy monitoring technology and a listing of demonstrated monitoring approaches are also presented.  相似文献   
6.
Abstract

The capping of stationary source emissions of NOx in 22 states and the District of Columbia is federally mandated by the NOx SIP Call legislation with the intended purpose of reducing downwind O3 concentrations. Monitors for NO, NO2, and the reactive oxides of nitrogen into which these two compounds are converted will record data to evaluate air quality model (AQM) predictions. Guidelines for testing these models indicate the need for semicontinuous measurements as close to real time as possible but no less frequently than once per hour. The measurement uncertainty required for AQM testing must be less than ±20% (±10% for NO2) at mixing ratios of 1 ppbv and higher for NO, individual NOz component compounds, and NOy. This article is a review and discussion of different monitoring methods, some currently used in research and others used for routine monitoring. The performance of these methods is compared with the monitoring guidelines. Recommendations for advancing speciated and total NOy monitoring technology and a listing of demonstrated monitoring approaches are also presented.  相似文献   
7.
Ambient air spiked with 1-10 ppbv concentrations of 41 toxic volatile organic compounds (VOCs) listed in US Environmental Protection Agency (EPA) Compendium Method TO-14A was monitored using solid sorbents for sample collection and a Varian Saturn 2000 ion trap mass spectrometer for analysis. The adsorbent was a combination of graphitic carbon and a Carboxen-type carbon molecular sieve. The method detection limits (MDLs) for 11 samples were typically 0.5 parts per billion by volume (ppbv) and lower except for bromomethane and chloromethane, both of which exhibited breakthrough. Thirty-day sample storage on the sorbents resulted in less than a 20% change for most compounds, and water management was required for humid samples to avoid major anomalous decreases in response during analyses. The adsorbent-based system, a system using canister-based monitoring, and a semi-continuous automated GC/MS (autoGC) monitoring system with a Tenax GR/Carbotrap B/Carbosieve S-III adsorbent preconcentrator were compared using spiked ozone concentrations as a variable. In this comparison, the target compounds included a number of n-aldehydes as well as those listed in TO-14A. The effects of ozone on the TO-14A compounds were relatively minor with the exception of negative artifacts noted for styrene and 1,1,2,2-tetrachloroethane. However, a small, systematic decrease in response was evident for a number of aromatic VOCs and 1,1,2,2-tetrachloroethane when ozone was increased from 50 to 300 ppbv. Method averages for multiple runs under the same conditions were typically within +0.25 ppbv of their mean for most compounds. For n-aldehydes, strong positive artifacts using the autoGC preconcentrator and strong negative artifacts for the canister-based and carbon sorbent approaches caused major disagreement among methods. These artifacts were mostly eliminated by using MnO2 ozone scrubbers, although loss of the n-aldehydes for all methods occurred after a single sample collection of 1 h duration, apparently due to the interaction of the n-aldehydes and products of the O3, MnO2 reaction on the scrubber.  相似文献   
8.
Ambient air samples from various studies were analyzed for a specific set of trace-level volatile organic compounds by using a gas chromatograph (GC) equipped with a flame ionization detector (FID) in parallel with an electron capture detector (ECD). The samples were then reanalyzed on a second GC system equipped with a mass selective detector (MSD). GC-FID/ECD data were compared to the nominally correct GC-MSD data to determine the accuracy of the nonspecific detectors, which often do not differentiate the targeted compound from Interfering compounds. Qualitative accuracy (capability for correctly identifying compounds on the basis of retention time only) and quantitative accuracy (capability for correctly measuring the concentration of an identified compound on the basis of peak area) were evaluated. Data are presented on a per-compound basis to provide the combined typical results from air samples collected in three geographic regions: Kanawha Valley, WV; Los Angeles, CA, area; and Houston, TX.  相似文献   
9.
A long-path Fourier transform spectrometer was used to make measurements of volatile organic compounds in an industrial complex in New Castle, Delaware as part of the Superfund Innovative Technology Evaluation (SITE) program. These data are compared to data taken with a whole-air canister technique. To provide an effective comparison the canisters were transported along the path for a 32-min period. For each FTIR spectrum, 256 interferograms were co-added over a 4-mln period. Eight individual spectra were then co-added to obtain the comparison data.  相似文献   
10.
陕西民俗文化旅游资源丰富,具有较高的社会价值和旅游价值,但由于政府部门的疏于重视和广大民众认识的浅薄,导致陕西民俗文化旅游资源受到严重的破坏,同时也造成不良风气的大量出现,使这些价值未能得以发挥.针对这一现状,以全国民俗文化的保护和开发为参照,结合陕西民俗文化旅游资源的自身特点,从保护和发展两个方面涉及的具体问题为出发点,就具体的问题提出了具体的建议,希望以此引起各方重视.参5.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号