Environmental Science and Pollution Research - Groundwater is a major resource for water supply in Canada, and 43 of 68 Saskatchewan municipalities rely on groundwater or combined groundwater and... 相似文献
Fifty percent of the dry zone areas in Sri Lanka have fluoride levels above 1 ppm. This paper discusses the ground conditions and recommends an appropriate range of fluoride in drinking water which can support preventive practices for improving the oral health of children 8-years old and younger. In efforts to address the Chronic Kidney Disease of Unknown etiology (CKDU), water treatment to reduce contaminant level in potable water has been implemented. Such treatment would also remove fluoride and has resulted in potable water with various fluoride levels, depending on concentrations in the raw water. While it is important to reduce fluoride levels, it is important to have appropriate residual levels for prevention of dental caries. It needs, however, to be noted fluoride in excess can cause dental fluorosis. In Sri Lanka's dry zone areas increasing prevalence of dental fluorosis with decreasing prevalence of dental caries has been noted. Consumption of tea and powdered milk could increase total intake of fluoride. Fluoridated toothpaste, when used properly, may, however, result in negligible intake of fluoride. Sri Lanka's hot tropical climate which results in substantial intake of fluids reinforces the need to consider reduction in water fluoride. Consideration of local studies and international standards indicate fluoride levels should be in the range of 0.225–0.500 ppm. In the range of 0.225–0.500 ppm, the prevalence of dental fluorosis and caries was only 14% and 8%, respectively, in an endemic district. When fluoride levels are above 0.500 ppm, the issue of dental fluorosis shall need to be addressed. When levels are below 0.225 ppm, oral health care services shall need to be directed at preventing dental caries. 相似文献
Diadromous fish often enter freshwater directly from seawater via fish ladders or channels built in estuarine dams. The oxygen consumption rates (OCR) of glass eel, Anguilla japonica, were determined using an automatic intermittent flow respirometer under various salinity and temperature regimes to physiologically explain this direct movement. The endogenous rhythm of the OCR in wild glass eels, freshly collected from estuaries, was nearly synchronous with the tidal pattern at the estuarine collection site. When the salinity was changed from 20 psu (12°C) at a constant temperature to that of freshwater, the OCR of the glass eels decreased by 21.6±7.0% (mean ± SD) (P<0.05), showing a dampened rhythm for about 48 h. After this period of impediment, the glass eels resumed normal metabolic activity. Direct migration from seawater to freshwater under constant temperature would result in a severe physiological stress for these glass eels for about two days. When the glass eels were exposed to a cyclic change in water temperature of 2°C 26 h−1, as they encounter in estuaries, and then were introduced to freshwater abruptly, the OCR rhythm corresponded to the cyclic changes in water temperature after exposure to freshwater. Under these conditions, the mean OCR of the glass eels had a small difference before and after exposure to freshwater. These data explained how glass eels can directly move from sea water into the freshwater without any apparent metabolic stress in the estuaries showing cyclic change in water temperature (Δt=2°C). 相似文献
Bioremediation emphasizes the detoxification and destruction of toxic substances by microorganisms. Wastewater obtained from an industrial concern was solvent extracted with methyl alcohol and dichloromethane and analysed by GC/MS. Besides phenol, a large variety of organic compounds were detected. Under controlled laboratory conditions, the wastewater was innoculated with a mixed culture of microorganisms specially selected for their abilities to degrade phenol. Samples were collected at regular intervals from the stirred tank bioreactor and analysed for phenol by reverse phase HPLC with a C18 column. Results shows that from an initial phenol concentration of 987 ppm, slightly more than 50% was destroyed within 163 hours. The dry weight of the microorganisms and the plate count (CFU/ml) shows a steady increase from 0.5238 gms to 0.5355 gms and from 1.1E+9 to 1.94E+13 respectively over the same period. This suggested that the phenol was consumed by the microorganisms as the sole carbon source. 相似文献
Intrauterine fetal demise (IUFD) in one of twins at 12 weeks of gestation was accompanied by markedly elevated maternal serum alpha-fetoprotein (AFP) at 17 and 18 weeks. Amniotic fluid AFP from the healthy surviving twin's sac at 18·5 and 23 weeks was also greatly increased along with a positive acetylcholinesterase (AChE) band. Persistently elevated AFP and positive AChE so long after fetal demise–-6·5 and 11 weeks post IUFD–-has not, to our knowledge, been previously described. In similar cases, high level ultrasound and careful placental examination at birth should be utilized to search for fetal abnormalities or multiple pregnancy with IUFD. 相似文献
Although Internet cafes have been designated as nonsmoking areas in Korea, smoke-free legislation has allowed the installation of indoor smoking rooms. The purposes of this study were to determine secondhand smoke (SHS) leakage from an Internet café smoking room and to identify factors associated with SHS leakage. PM2.5 (particulate matter with an aerodynamic diameter ≤2.5 μm) mass concentrations were measured simultaneously both inside and outside the door to the smoking room. During each measurement, a field technician observed how long the smoking room door was opened and closed, the direction of door opening, and the number of smokers. A multivariate linear regression model was used to identify the causality of SHS leakage from the smoking room. A time series of PM2.5 concentrations both inside and outside the door to the smoking room showed a similar trend. SHS leakage was significantly increased because of factors associated with the direction of the smoking room door being opened, the duration of how long the smoking room door was opened until it was closed, and the average PM2.5 concentration inside the smoking room when the door was opened. SHS leakage from inside the smoking room to outside the smoking room was evident especially when the smoking room door was opened. Since the smoking room is not effective in preventing SHS exposure, the smoking room should be removed from the facilities to protect citizens from SHS exposure through revision of the current legislation, which permits installation of a smoking room.
Implications: This paper concerns secondhand smoke (SHS) leakage from indoor smoking room. Unlike previous studies, the authors statistically analyzed the causality of PM2.5 concentration leakage from a smoking room using time-series analysis. Since the authors selected the most common smoking room, the outcomes could be generalized. The study demonstrated that SHS leakage from smoking room and SHS leakage were clearly associated with door opening. The finding demonstrated ineffectiveness of smoking room to protect citizens and supports removal of indoor smoking room. 相似文献
High Canadian waste disposal rates necessitate landfill gas monitoring and accurate forecasting. CO2 estimates in LandGEM version 3.02 currently rest on the assumptions that CO2 is a function of CH4, where the two gases make up nearly 100% of landfill gas content, leading to overestimated CO2 collection estimates. A total of 25 cases (five formulas, five approaches) compared annual CO2 collection at four western Canadian landfills. Despite common use in literature, the 1:1 ratio of CH4 to CO2 was not recommended to forecast landfill gas collection in cold climates. The existing modelling approach significantly overestimated CO2 production in three of four sites, resulting in the highest residual sum of squares. Optimization resulted in the most accurate results for all formulas and approaches, which had the greatest reduction in residual sums of squares (RSS) over the default approach (60.1 to 97.7%). The 1.4 Ratio approach for Lo:Lo-CO2 yielded the second most accurate results for CO2 flow (mean RSS reduction of 50.2% for all sites and subsection models). The annual k-modified LandGEM calculated k’s via two empirical formulas (based on precipitation) and yielded the lowest accuracy in 12 of 20 approaches. Unlike other studies, strong relationships between optimized annual k’s and precipitation were not observed.