Objective: Reoperative coronary bypass grafting is at high risk. Particularly in redo cases where the patent graft is running near
the midline of the sternum, the graft may be exposed to injury by a median sternotomy and subsequent dissection. Whereas,
off-pump bypass grafting from the left axillary artery or descending thoracic artery by a left thoracotomy approach is safe
for preventing graft damage.Methods: From March 1998 to February 2002, we performed off-pump coronary artery bypass grafting by a left thoracotomy approach in
9 patients. The left axillary artery was used as the inflow vessel in 4 cases, and the descending thoracic, aorta in 5.Results: The radial artery was anastomosed proximally to the axillary artery in 4 cases and the descending thoracic aorta in one
case. The saphenous vein graft was anastomosed, proximally to the descending thoracic aorta in 4 cases. Transdiaphragmatic
minimally invasive bypass grafting for the right coronary artery was simultaneously performed in 3 cases. Postoperative cardiac
events were ventricular arrhythmia in 6 cases and supraventricular arrhythmia in 3 cases. There was no damage to the patent
grafts. Postoperative coronary angiography performed, in 8 cases revealed all the grafts to be patent without stenosis. Cardiac
symptoms were not found after the operation in any of the cases.Conclusions: These procedures can prevent the injury to patent grafts caused by a median sternotomy, and will be one of the useful strategies
for reoperative off-pump coronary artery bypass grafting. 相似文献
Background: We evaluated the ability of the standards issued by the Danish Society of Anaesthesiologists to reflect a blood loss. Methods: In 9 pigs bled (0–24 ml kg-1) and retransfused (to 28 ml kg-1) during halothane anaesthesia, central cardiovascular, thoracic electrical impedance (TI), oxygen, acid-base and temperature variables were recorded. Results: With the recommendation for minor surgery (mean arterial pressure (MAP) and heart rate (HR)), the correlation to the blood loss was 0.74 ( P < 0.001) and with that for major surgery (MAP, HR, central venous pressure (CVP) and rectal temperature (Tempr)) it was 0.79 ( P < 0.001). With the recommendation for extensive surgery (MAP, HR, CVP, pulmonary artery catheter variables and the central-peripheral temperature difference (ΔTempr-t)), the correlation was 0.84 ( P < 0.001). Non-invasive monitoring (MAP, HR, ΔTempr-t TI and near-infrared spectroscopy of the brain (SinvosO2)) was only slightly better than basal monitoring (r=0.76, P < 0.001). However, adding arterial base excess (BE), TI and peripheral temperature (Tempt) to the recommendation for major surgery resulted in a correlation of 0.87 ( P < 0.001), while adding BE and TI to the recommendation for extensive surgery raised correlation to only 0.88 ( P < 0.001). Conclusion: When the recommendations were followed the correlation to the blood loss ranged from 0.74–0.84. However, with the recording of MAP, HR, CVP, ΔTempr-t, BE and TI a correlation of 0.87 was achieved, indicating that a pulmonary artery catheter may not be in need for patients undergoing surgical procedures with expected haemorrhage. 相似文献
Background. The “elephant trunk” technique, using a free-floating vascular prosthesis, was originally described to facilitate a subsequent operation on the downstream aorta. We developed an additional refinement of this technique, called the “bidirectional elephant trunk.” This option may represent an interesting tool in more complex aortic operations, especially when the descending aorta has to be replaced first in patients with concomitant pathology of the ascending aorta or of the aortic arch.
Methods. The initial operation is performed through a left thoracotomy. The proximal elephant trunk is created by invaginating the future aortic arch graft into the descending aortic graft. The proximal anastomosis between the doubled graft and the proximal descending aorta is performed first. During construction of the distal anastomosis, a distal elephant trunk may be inserted likewise. If the aortic arch and ascending aorta have to be replaced later, this second step is performed through a median sternotomy. The free-floating arch graft is pulled out of the proximal descending aorta with a nerve hook, unfolded, and used for total arch replacement.
Results. This technique was used successfully in 3 patients without mortality. No major complications were observed excepted persistent hoarseness in a patient with preoperative paresis of the recurrent nerve. No perfusion problems due to the unfolding of the free-floating graft occurred during the second operation.
Conclusions. The bidirectional elephant trunk technique is an interesting option that may be suitable for patients presenting with a complex pathology of the whole thoracic aorta when the descending segment has to be replaced first. 相似文献
We describe the successful postoperative pain management in an 11-month-old infant who underwent bilateral thoracotomy, using continuous infusions of bupivacaine into two directly placed paravertebral catheters. Haemodynamic parameters and pain scores were measured 1–2 h for 60 h while the infusions were continued and, intermittently, blood samples were taken for subsequent measurement of serum bupivacaine concentrations. The technique provided effective pain relief and the infant required no other analgesia postoperatively. There were no adverse haemodynamic consequences or complications relating to either catheter placement or drug infusions. Serum concentrations of bupivacaine remained below toxic levels throughout the study period, though accumulation did occur. 相似文献