4 patients with a mean age of 20 years and isolated congenital radial head dislocation (1 unilateral anterior, 1 unilateral posterior and 2 bilateral anterior dislocations) were all pain-free and had almost normal elbow function. 相似文献
Two recently discovered genes, the recombination activating genes 1 and 2 (RAG-1 and RAG-2), are necessary to perform variable (V), diversity (D), and joining (J) recombination. They synergistically activate VDJ recombination to generate immunocompetent lymphocytes. Disruption of either gene results in a maturation arrest at a very early B and T cell progenitor stage. Expression and downregulation of RAG's are closely associated with interleukin 7, sIgM and TCR-CD3 complex, respectively. Assessment of RAG mRNA expression is a valuable marker in identifying the genotypic maturation status of leukemias and lymphomas. Persistent RAG expression in otherwise mature lymphoid proliferations may explain puzzling biological and clinical observations such as multiple rearrangements in lymphomas with a mature phenotype. Lack of RAG expression in Hodgkin's disease with abundant Reed-Stern-berg cells is consistent with a mature phenotype of the latter. Availability of a anti-RAG-1 monoclonal antibody in the near future will facilitate RAG analysis of lymphomas. 相似文献
This study aimed to examine the influence of acute tissue hypoxygenation on the expression of immediate early genes in different
rat tissues. To this end male Sprague-Dawley rats were exposed to 0.1% carbon monoxide for 0.5, 1 and 6 h or to 9% oxygen
for 6 h and mRNA levels for c-jun, c-fos, c-myc and EGR-1 were assayed by RNase protection in hearts, kidneys, livers and lungs. We found that hypoxia increased c-jun mRNA levels between twofold (lung) and eightfold (liver) in all organs examined; c-fos mRNA increased between threefold (lung) and 20-fold (heart); c-myc mRNA increased between twofold (lung) and sixfold (heart); and EGR-1 mRNA increased between twofold (lung) and sixfold (heart).
Our findings suggest that acute tissue hypoxygenation is a general stimulus of the expression of immediate early genes in
vivo. With regard to the sensitivity to hypoxia, organ differences appear to exist in that the lung is rather insensitive,
whilst the heart is rather sensitive.
Received: 25 February 1997 / Received after revision: 17 June 1997 / Accepted: 19 June 1997 相似文献
Background: Lumbar facet nerve (medial branch) blocks are often used to diagnose facet joint-mediated pain. The authors recently described a new ultrasound-guided methodology. The current study determines its accuracy using computed tomography scan controls.
Methods: Fifty bilateral ultrasound-guided approaches to the lumbar facet nerves were performed in five embalmed cadavers. The target point was the groove at the cephalad margin of the transverse (or costal) process L1-L5 (medial branch T12-L4) adjacent to the superior articular process. Axial transverse computed tomography scans, with and without 1 ml contrast dye, followed to evaluate needle positions and spread of contrast medium.
Results: Forty-five of 50 needle tips were located at the exact target point. The remaining 5 were within 5 mm of the target. In 47 of 50 cases, the applied contrast dye reached the groove where the nerve is located, corresponding to a simulated block success rate of 94% (95% confidence interval, 84-98%). Seven of 50 cases showed paraforaminal spread, 5 of 50 showed epidural spread, and 2 of 50 showed intravascular spread. Despite the aberrant distribution, all of these approaches were successful, as indicated by contrast dye at the target point. Abnormal contrast spread was equally distributed among all lumbar levels. Contrast traces along the needle channels were frequently observed. 相似文献
Objective: This prospective study was designed to compare incidence and clinical significance of ventricular late potentials between patients with idiopathic dilated cardiomyopathy (IDC) and postinfarct patients (CAD) using exactly the same method of signal-averaged electrocardiography (SAECG) in both patient groups. Methods: Time-domain analysis of SAECG was performed in 120 consecutive patients with IDC, 120 patients with CAD, and 60 healthy controls. Ventricular late potentials were detected in 27 of 120 patients with IDC (23%) compared to 41 of 120 patients with CAD (34%; P < 0.05). Results: Ventricular late potentials were found in 2 of 60 controls (3%). During 15 ± 7 months follow-up, serious arrhythmic events occurred in 17 of 120 patients with IDC (14%) and in 13 of 120 patients with CAD (11%). The sensitivity of ventricular late potentials for future arrhythmic events was 35% for IDC compared to 77% for CAD (P < 0.05). The positive predictive value of late potentials detected by time-domain analysis was 22% for IDC versus 24% for CAD (P = ns). Conclusion: In this selected patient population with IDC and CAD, time-domain analysis of SAECG revealed a lower incidence of ventricular ate potentials in patients with IDC as compared to postinfarct patients. Whereas ventricular late potentials had a high sensitivity but a low positive predictive value for identification of postinfarct patients with serious arrhythmic events during follow-up, both sensitivity and positive predictive value of ventricular late potentials for future serious arrhythmic events were low in the setting of IDC. 相似文献
Background/aims: Quantitative measurement of skin roughness has proved to be a valuable tool in the efficacy-control of external applications, but it suffers from not yielding easily comparable results. The most important sources of inter-observer variability are high-pass filters used to separate roughness and waviness, and low-pass filters which result from the finite resolution of the instrument or from the finite sampling interval of digital measurement. In the present study, the effects of high-pass filters and sampling intervals on the roughness measured were investigated. Methods: Dynamically focusing optical profilometry was used to measure the surfaces of negative replicas of healthy human skin. High-pass cut-off wavelengths and sampling intervals were varied systematically. Results/conclusions: Virtually unbiased estimates for the roughness parameters K, Sk, Rq, and Ra can be obtained using sampling intervals of 40 or even 80 μm. Regarding these roughness parameters, it is far better to do more scans than to shorten the sampling interval. The roughness parameters Rz, Rp, Rt, Rpm, Rmax, Pt, on the other hand are very sensitive to the influence of the sampling interval; to achieve satisfying estimates, the sampling interval should be no longer than 2 to 5 urn; as an important parameter’of the measurement, it is worthy of remark and should always be indicated. The way the mean square roughness Rq depends on the cut-off wavelength is not well described by the Sayles-Thomas-relation Rq~λc0.5. If the power-spectrum |h*(v)|2 approximates sufficiently to a power law, |h*(v)|2~vδ, a better estimate is given by Rq~λcγ with γ=-(δ+1)/2. In many cases, γ=1 or Rq~λc will suffice. 相似文献
The technical equipment of today's intensive care unit (ICU) workstation has been characterized by a gradual, incremental accumulation of individual devices, whose presence is dictated by patient needs. These devices usually present differently designed controls, operate under different alarm philosophies, and cannot communicate with each other. By contrast, ICU workstations could be equipped permanently and in a standardized manner with electronically linked modules if the attending physicians could reliably predict, at the time of admission, the patient's equipment needs. Over a period of 3 1/2 months, the doctors working in our 20-bed surgical ICU made 1,000 predictions concerning outcome, equipment need, duration of artificial ventilation, and duration of hospitalization for 300 recently admitted patients. The interviews were made within the first 24 hours after admission. The doctors being interviewed were usually (i.e., in over 90% of cases) unfamiliar with the patient. Information concerning the patient's general state of health, special pre-ICU events, and complications was offered to the interviewed clinician because this information represents standard admission data. It was found that the equipment need (represented by two different setups, high tech and low tech) could be predicted most reliably (96.4% correct predictions) compared with a prediction on outcome of ICU treatment (94.5%), on duration of artificial ventilation (75.4%), and on duration of stay (43.4%). There was no significant (p>0.05) difference in the reliability of predictions between residents and consultants. Factors influencing the postoperative equipment need varied with surgical specialty. The general state of health, as indicated by the ASA classification (p<0.001), and the specific intervention (all multiple-valve replacements needed the high-level equipment standard) appeared to be most important in cardiac surgery, while a state of septicemia was important in general surgery (p<0.001). Our findings suggest that ICU workstations may be standardized into at least two types. 相似文献